New methodical and instrumental developments in laser ablation inductively coupled plasma mass spectrometry

被引:20
作者
Hoffmann, E
Lüdke, C
Skole, J
Stephanowitz, H
Wollbrandt, J
Becker, W
机构
[1] Institutsteil Berlin, Inst Spektrochem & Angew Spekt, D-12489 Berlin, Germany
[2] Gesell Forderung Angewandter Opt Optoelekt Quante, D-12489 Berlin, Germany
[3] Becker & Hickl GmbH, D-12277 Berlin, Germany
关键词
laser ICP-MS; signal standardization; representative sample mass; time-of-flight mass spectrometer;
D O I
10.1016/S0584-8547(02)00109-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Many tasks in bulk analysis, micro analysis and depth profile analysis can be solved advantageously by laser ablation inductively coupled plasma mass spectrometry (Laser ICP-MS) in particular, when both the chemical and elemental distributions in the sample are to be determined. However, the analyst has to take into account that the analytical precision and accuracy of the Laser ICP-MS is influenced decisively by signal standardization, the homogeneity of the samples as well as calibration standards and the mass-spectrometric measuring mode, which is usually sequential when performed with scanning mass spectrometers such as quadrupol- or sector-based instruments. Using the ablated mass as standard, an excellent level of the analytical precision and accuracy (relative standard deviation R.S.D. < 0.5%) has been obtained for homogeneous sample materials such as alloys, For inhomogeneous samples, such as pressed pellets, a statistical test is described, which is based upon the auto-correlation function to characterize the sample inhomogeneity. The application of the test allows us to calculate the representative mass for the quantitative analysis at previously defined analytical precision. In the instrumental part of the paper a new type of an ICP-time-of-flight (TOF) mass spectrometer-is described, constructed and built up in our laboratory. For fast signal counting an application-specific integrated circuit (ASIC) was developed, which permits a time resolution of I ns. The analytical performance of the TOF when used in combination with an ICP is demonstrated in terms of resolution, ion extraction rate, detection limits and dynamic range. The determination of K-39 and Ca-40(+) at trace level can be realized in a cool plasma condition (high central gas flow) only with a small interference by Ar-40(+). Detection limits of 23 elements were measured with typical values in the lower nanograms per liter range. The ion extraction rates, measured for a sample mass of I ng in terms of counts per second divided by the relative isotope abundance, are one order of magnitude higher than those obtained with a quadrupol-based instrument. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:1535 / 1545
页数:11
相关论文
共 49 条
[1]   SIMULTANEOUS MEASUREMENT OF ISOTOPE RATIOS IN SOLIDS BY LASER-ABLATION WITH A TWIN QUADRUPOLE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER [J].
ALLEN, LA ;
PANG, HM ;
WARREN, AR ;
HOUK, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) :267-271
[2]   LASER ABLATION OF SOLIDS FOR ELEMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1437-1444
[3]   ENTRAINMENT AND TRANSPORT OF LASER ABLATED PLUMES FOR SUBSEQUENT ELEMENTAL ANALYSIS [J].
ARROWSMITH, P ;
HUGHES, SK .
APPLIED SPECTROSCOPY, 1988, 42 (07) :1231-1239
[4]  
Becker JS, 1996, FRESEN J ANAL CHEM, V355, P626
[5]   PRECISION AND ACCURACY OF LASER ABLATION-ICP-MS ANALYSIS OF RARE-EARTH ELEMENTS WITH EXTERNAL CALIBRATION [J].
COUSIN, H ;
MAGYAR, B .
MIKROCHIMICA ACTA, 1994, 113 (3-6) :313-323
[6]   FRACTIONATION EFFECTS IN LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CROMWELL, EF ;
ARROWSMITH, P .
APPLIED SPECTROSCOPY, 1995, 49 (11) :1652-1660
[7]   SEMIQUANTITATIVE ANALYSIS WITH LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CROMWELL, EF ;
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :131-138
[8]   INTERACTION OF LASER-RADIATION WITH SOLID MATERIALS AND ITS SIGNIFICANCE TO ANALYTICAL SPECTROMETRY - A REVIEW [J].
DARKE, SA ;
TYSON, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :145-209
[9]   A STUDY OF LASER ABLATION AND SLURRY NEBULIZATION SAMPLE INTRODUCTION FOR THE ANALYSIS OF GEOCHEMICAL MATERIALS BY INDUCTIVELY COUPLED PLASMA SPECTROMETRY [J].
DARKE, SA ;
LONG, SE ;
PICKFORD, CJ ;
TYSON, JF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03) :284-289
[10]  
DENOYER ER, 1991, ANAL CHEM, V63, P445