Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: a method for molecular imaging and targeted drug delivery

被引:255
作者
Hynynen, Kullervo
McDannold, Nathan
Vykhodtseva, Natalia
Raymond, Scott
Weissleder, Ralph
Jolesz, Ferenc A.
Sheikov, Nickolai
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Ctr Mol Imaging Res, Boston, MA 02114 USA
关键词
blood-brain barrier; drug delivery system; ultrasonics; ultrasound contrast agent; magnetic resonance imaging; FOCUSED ULTRASOUND; RABBIT; PERMEABILITY; COMPILATION; PRESSURE; THERAPY; MRI;
D O I
10.3171/jns.2006.105.3.445
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The goal of this study was to explore the feasibility of using low-frequency magnetic resonance (MR) image-guided focused ultrasound as a noninvasive method for the temporary disruption of the blood-brain barrier (BBB) at targeted locations. Methods. Rabbits were placed inside a clinical 1.5-tesla MR imaging unit, and sites in their brains were targeted for 20-second burst sonications (frequency 260 kHz). The peak pressure amplitude during the burst varied between 0.1 and 0.9 MPa. Each sonication was performed after an intravenous injection of an ultrasound contrast agent (Optison). The disruption of the BBB was evaluated with the aid of an injection of an MR imaging contrast agent (MAG-NEVIST). Additional tests involving the use of MION-47, a 20-nm magnetic nanoparticle contrast agent, were also performed. The animals were killed at different time points between 3 minutes and 5 weeks postsonication, after which light or electron microscopic evaluation was performed. The threshold for BBB disruption was approximately 0.2 MPa. More than 80% of the brain sites sonicated showed BBB disruption when the pressure amplitude was 0.3 MPa; at 0.4 MPa, this percentage was greater than 90%. Tissue necrosis, ischemia, and apoptosis were not found in tissue in which the pressure amplitude was less than 0.4 MPa; however, in a few areas of brain tissue erythrocytes were identified outside blood vessels following exposures of 0.4 MPa or higher. Survival experiments did not show any long-term adverse events. Conclusions. These results demonstrate that low-frequency ultrasound bursts can induce local, reversible disruption of the BBB without undesired long-term effects. This technique offers a potential noninvasive method for targeted drug delivery in the brain aided by a relatively simple low-frequency device.
引用
收藏
页码:445 / 454
页数:10
相关论文
共 29 条
[1]   Transporting therapeutics across the blood-brain barrier [J].
Abbott, NJ ;
Romero, IA .
MOLECULAR MEDICINE TODAY, 1996, 2 (03) :106-113
[2]   Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans [J].
Aubry, JF ;
Tanter, M ;
Pernot, M ;
Thomas, JL ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :84-93
[3]   In vivo target-specific delivery of macromolecular agents with MR-guided focused ultrasound [J].
Bednarski, MD ;
Lee, JW ;
Callstrom, MR ;
Li, KCP .
RADIOLOGY, 1997, 204 (01) :263-268
[4]   IDENTIFICATION OF PROGRAMMED CELL-DEATH INSITU VIA SPECIFIC LABELING OF NUCLEAR-DNA FRAGMENTATION [J].
GAVRIELI, Y ;
SHERMAN, Y ;
BENSASSON, SA .
JOURNAL OF CELL BIOLOGY, 1992, 119 (03) :493-501
[5]   COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES .2. [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (01) :93-108
[6]   COMPREHENSIVE COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 (02) :423-457
[7]   Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications [J].
Hynynen, K ;
McDannold, N ;
Sheikov, NA ;
Jolesz, FA ;
Vykhodtseva, N .
NEUROIMAGE, 2005, 24 (01) :12-20
[8]   500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls [J].
Hynynen, K ;
Clement, GT ;
McDannold, N ;
Vykhodtseva, N ;
King, R ;
White, PJ ;
Vitek, S ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :100-107
[9]   Demonstration of potential noninvasive ultrasound brain therapy through an intact skull [J].
Hynynen, K ;
Jolesz, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (02) :275-283
[10]   Trans-skull ultrasound therapy: The feasibility of using image-derived skull thickness information to correct the phase distortion [J].
Hynynen, K ;
Sun, J .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (03) :752-755