Recent and Future Directions in CT Imaging

被引:99
作者
Pelc, Norbert J. [1 ,2 ]
机构
[1] Stanford Univ, James H Clark Ctr, Dept Bioengn, Stanford, CA 94305 USA
[2] Stanford Univ, James H Clark Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
Computed tomography; Image quality; Technology trends; COMPUTED-TOMOGRAPHY; INCREASING UTILIZATION; EMERGENCY-DEPARTMENT; QUALITY; SYSTEM; NOISE;
D O I
10.1007/s10439-014-0974-z
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Computed tomography (CT) has made enormous technical advances since its introduction into clinical use. The engineering improvements have in turn led to important clinical applications and large impact in patient care. This paper reviews the technology development trends in CT since its introduction and uses these trends to help illuminate likely future progress. The prediction is that significant further improvements in speed, spatial resolution and dose efficiency can be expected in the next decade.
引用
收藏
页码:260 / 268
页数:9
相关论文
共 22 条
[1]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]
[Anonymous], 2009, 160 NCRP
[3]
[Anonymous], 2009, Computed Tomography: Principles, Design Artifacts and Recent Advances
[4]
To bin or not to bin? The effect of CT system limiting resolution on noise and detectability [J].
Baek, Jongduk ;
Pineda, Angel R. ;
Pelc, Norbert J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05) :1433-1446
[5]
Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[6]
CARDIAC COMPUTED-TOMOGRAPHY [J].
BOYD, DP ;
LIPTON, MJ .
PROCEEDINGS OF THE IEEE, 1983, 71 (03) :298-307
[7]
Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006 [J].
Broder J. ;
Fordham L.A. ;
Warshauer D.M. .
Emergency Radiology, 2007, 14 (4) :227-232
[8]
Increasing utilization of computed tomography in the adult emergency department, 2000-2005 [J].
Broder J. ;
Warshauer D.M. .
Emergency Radiology, 2006, 13 (1) :25-30
[9]
NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY [J].
CHESLER, DA ;
RIEDERER, SJ ;
PELC, NJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :64-74
[10]
Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation [J].
Christner, Jodie A. ;
Zavaletta, Vanessa A. ;
Eusemann, Christian D. ;
Walz-Flannigan, Alisa I. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W49-W55