Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation

被引:83
作者
Christner, Jodie A. [1 ]
Zavaletta, Vanessa A. [1 ]
Eusemann, Christian D. [1 ,2 ]
Walz-Flannigan, Alisa I. [1 ]
McCollough, Cynthia H. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Siemens Healthcare, Malvern, PA USA
基金
美国国家卫生研究院;
关键词
CT; dose efficiency; helical CT; overscanning; radiation dose; COMPUTED-TOMOGRAPHY; RADIATION; VOLUME;
D O I
10.2214/AJR.09.2878
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of this study was to measure the dose reduction achieved with dynamically adjustable z-axis collimation. MATERIALS AND METHODS. A commercial CT system was used to acquire CT scans with and without dynamic z-axis collimation. Dose reduction was measured as a function of pitch, scan length, and position for total incident radiation in air at isocenter, accumulated dose to the center of the scan volume, and accumulated dose to a point at varying distances from a scan volume of fixed length. Image noise was measured at the beginning and center of the scan. RESULTS. The reduction in total incident radiation in air at isocenter varied between 27% and 3% (pitch, 0.5) and 46% and 8% (pitch, 1.5) for scan lengths of 20 and 500 mm, respectively. Reductions in accumulated dose to the center of the scan were 15% and 29% for pitches of 0.5 and 1.5 for 20-mm scans. For scan lengths greater than 300 mm, dose savings were less than 3% for all pitches. Dose reductions 80 mm or farther from a 100-mm scan range were 15% and 40% for pitches of 0.5 and 1.5. With dynamic z-axis collimation, noise at the extremes of a helical scan was unchanged relative to noise at the center. Estimated reductions in effective dose were 16% (0.4 mSv) for the head, 10% (0.8 and 1.4 mSv) for the chest and liver, 6% (0.8 mSv) for the abdomen and pelvis, and 4% (0.4 mSv) and 55% (1.0 mSv) for coronary CT angiography at pitches of 0.2 and 3.4. CONCLUSION. Use of dynamic z-axis collimation reduces dose in helical CT by minimizing overscanning. Percentage dose reductions are larger for shorter scan lengths and greater pitch values.
引用
收藏
页码:W49 / W55
页数:7
相关论文
共 12 条
[1]
Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume [J].
Boone, JM ;
Cooper, VN ;
Nemzek, WR ;
McGahan, JP ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (10) :2393-2407
[2]
COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[3]
*EUR COMM, 2000, EUR GUID QUAL CRIT C
[4]
Primary radiation outside the imaged volume of a multislice helical CT scan [J].
Nicholson, R ;
Fetherston, S .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (894) :518-522
[5]
Female breast radiation exposure during CT pulmonary angiography [J].
Parker, MS ;
Hui, FK ;
Camacho, MA ;
Chung, JK ;
Broga, DW ;
Sethi, NN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (05) :1228-1233
[6]
Shrimpton P., 2004, European Guidelines for Multislice Computed Tomography Funded by the European Commission
[7]
Stierstorfer K, 2007, RADIOLOGICAL SOC N A
[8]
Minimization of over-ranging in helical volumetric CT via hybrid cone beam image reconstruction - Benefits in dose efficiency [J].
Tang, Xiangyang ;
Hsieh, Jiang ;
Dong, Fang ;
Fan, Jiahua ;
Toth, Thomas L. .
MEDICAL PHYSICS, 2008, 35 (07) :3232-3238
[9]
Energy imparted-based estimates of the effect of z overscanning on adult and pediatric patient effective doses from multi-slice computed tomography [J].
Theocharopoulos, Nicholas ;
Damilakis, John ;
Perisinakis, Kostas ;
Gourtsoyiannis, Nicholas .
MEDICAL PHYSICS, 2007, 34 (04) :1139-1152
[10]
The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations [J].
Tzedakis, A ;
Damilakis, J ;
Perisinakis, K ;
Stratakis, J ;
Gourtsoyiannis, N .
MEDICAL PHYSICS, 2005, 32 (06) :1621-1629