The radiologic anatomy of the lumbar and lumbosacral pedicles

被引:55
作者
Robertson, PA [1 ]
Stewart, NR [1 ]
机构
[1] Auckland Hosp, Dept Orthopaed Surg, Auckland, New Zealand
关键词
lumbar pedicle anatomy; pedicle radiology; pedicle screws;
D O I
10.1097/00007632-200003150-00010
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An anatomic and radiologic study of lumbar and lumbosacral pedicle anatomy. Objectives. To define the radiologic anatomy of the lumbar and first sacral pedicle in the coaxial projection. Summary of Background Data. Fluoroscopic assistance for pedicle screw placement requires radiologic landmarks. The radiologic landmarks have previously been assumed. Detailed study of the correlation between anatomy and radiology is required. Methods. Lumbar vertebrae and sacra were marked with radiopaque material to demonstrate the pedicle cortical borders. The vertebrae were then imaged in the coaxial projection to determine the correlation between the pedicle cortex and the radiologic image. Pedicle dimensions were recorded. Results. Pedicle dimensions were consistent with known measurements, yet the long axis of the L4 and L5 pedicle ellipse was oblique to the vertical. Consequently, the minor diameter of the pedicle ellipse was considerably less than the measured pedicle width at L5. The radiologic pedicle image was consistently within the true pedicle cortex, by up to 3 mm, and probably represents the in ner cortical border of the pedicle. The S1 pedicle has reliable anatomic landmarks, yet only the medial and superior borders were visualized. Conclusions. The radiologic pedicle image in the lumbar and lumbosacral spine is a reliable guide to the true bony cortex of the pedicle. At S1 the pedicle image is less well correlated with the cortical borders of the pedicle, yet other reliable anatomic landmarks exist.
引用
收藏
页码:709 / 715
页数:7
相关论文
共 46 条
[1]  
BANTA CJ, 1989, ORTHOPEDICS, V12, P939
[2]   PEDICLE DIAMETER DETERMINED BY COMPUTED-TOMOGRAPHY - ITS RELEVANCE TO PEDICLE SCREW FIXATION IN THE LUMBAR SPINE [J].
BERNARD, TN ;
SEIBERT, CE .
SPINE, 1992, 17 (06) :S160-S163
[3]   A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE [J].
BERRY, JL ;
MORAN, JM ;
BERG, WS ;
STEFFEE, AD .
SPINE, 1987, 12 (04) :362-367
[4]   STIMULUS-EVOKED EMG MONITORING DURING TRANSPEDICULAR LUMBOSACRAL SPINE INSTRUMENTATION - INITIAL CLINICAL-RESULTS [J].
CALANCIE, B ;
MADSEN, P ;
LEBWOHL, N .
SPINE, 1994, 19 (24) :2780-2786
[5]   In vitro simulation - Early results of stereotaxy for pedicle screw placement [J].
Carl, AL ;
Khanuja, HS ;
Sachs, BL ;
Gatto, CA ;
vomLehn, J ;
Vosburgh, K ;
Schenck, J ;
Lorensen, W ;
Rohling, K ;
Disler, D .
SPINE, 1997, 22 (10) :1160-1164
[6]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[7]   COMPUTED TOMOGRAPHIC OSTEOMETRY OF ASIAN LUMBAR PEDICLES [J].
CHEUNG, KMC ;
RUAN, D ;
CHAN, FL ;
FANG, D .
SPINE, 1994, 19 (13) :1495-1498
[8]   Radiographic assessment of pedicle hook placement [J].
Cheung, KMC ;
Luk, KDK ;
Leong, JCY .
SPINE, 1997, 22 (18) :2106-2111
[9]   Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement [J].
Clements, DH ;
Morledge, DE ;
Martin, WH ;
Betz, RR .
SPINE, 1996, 21 (05) :600-604
[10]  
Davne SH, 1992, SPINE S6, V17, P184, DOI DOI 10.1097/00007632-199206001-00021