Intelligent and automatic systems based on arrays of non-specific-response chemical sensors were recently developed in our laboratory. For multidetermination applications, the normal choice is an array of potentiometric sensors to generate the signal, and an artificial neural network (ANN) correctly trained to obtain the calibration model. As a great amount of information is required for the proper modelling, we proposed its automated generation by using the sequential injection analysis (SIA) technique. First signals used were steadystate: the equilibrium signal after a step-change in concentration. We have now adapted our procedures to record the transient response corresponding to a sample step. The novelty in this approach is therefore the use of the dynamic components of the signal in order to better discriminate or differentiate a sample. In the developed electronic tongue systems, detection is carried out by using a sensor array formed by five potentiometric sensors based on PVC membranes. For the developed application we employed two different chloride-selective sensors, two nitrate-selective sensors and one generic response sensor. As the amount of raw data (fivefold recordings corresponding to the five sensors) is excessive for an ANN, some feature extraction step prior to the modelling was needed. In order to attain substantial data reduction and noise filtering, the data obtained were fitted with orthonormal Legendre polynomials. In this case, a third-degree Legendre polynomial was shown to be sufficient to fit the data. The coefficients of these polynomials were the input information fed into the ANN used to model the concentrations of the determined species (Cl-, NO3-and HCO3-). Best results were obtained by using a backpropagation neural network trained with the Bayesian regularisation algorithm; the net had a single hidden layer containing three neurons with the tansig transfer function. The results obtained from the time-dependent response were compared with those obtained from steady-state conditions, showing the former superior performance. Finally, the method was applied for determining anions in synthetic samples and real water samples, where a satisfactory comparison was also achieved.
引用
收藏
页码:1186 / 1194
页数:9
相关论文
共 43 条
[1]   FLOW-THROUGH TUBULAR ION-SELECTIVE ELECTRODES RESPONSIVE TO ANIONIC SURFACTANTS FOR FLOW-INJECTION ANALYSIS [J].
ALONSO, J ;
BARO, J ;
BARTROLI, J ;
SANCHEZ, J ;
DELVALLE, M .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :115-121
[2]  
*AM SOC TEST MAT, 1982, D106770 AM SOC TEST
[3]   Theoretical and experimental studies of metallated phenanthroline derivatives as carriers for the optimization of the nitrate sensor [J].
Andredakis, GE ;
Moschou, EA ;
Matthaiou, K ;
Froudakis, GE ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2001, 439 (02) :273-280
[4]   Variable reduction on electronic tongue data [J].
Artursson, T ;
Spångeus, P ;
Holmberg, M .
ANALYTICA CHIMICA ACTA, 2002, 452 (02) :255-264
[5]   Wavelet transform of electronic tongue data [J].
Artursson, T ;
Holmberg, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (02) :379-391
[6]   Application of neural network calibrations to an halide ISE array [J].
Baret, M ;
Massart, DL ;
Fabry, P ;
Conesa, F ;
Eichner, C ;
Menardo, C .
TALANTA, 2000, 51 (05) :863-877
[7]   Halide ion-selective electrode array calibration [J].
Baret, M ;
Massart, DL ;
Fabry, P ;
Menardo, C ;
Conesa, F .
TALANTA, 1999, 50 (03) :541-558
[8]  
Bevington R., 1969, DATA REDUCTION ERROR
[9]   PROCESSING OF SIGNALS FROM AN ION-SELECTIVE ELECTRODE ARRAY BY A NEURAL NETWORK [J].
BOS, M ;
BOS, A ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1990, 233 (01) :31-39
[10]   Sequential injection system with higher dimensional electrochemical sensor signals Part 2.: Potentiometric e-tongue for the determination of alkaline ions [J].
Cortina, M ;
Gutés, A ;
Alegret, S ;
del Valle, M .
TALANTA, 2005, 66 (05) :1197-1206