Whole Heart Magnetization-Prepared Steady-State Free Precession Coronary Vein MRI

被引:12
作者
Stoeck, Christian T. [1 ,2 ,3 ]
Han, Yuchi [1 ,2 ]
Peters, Dana C. [1 ,2 ]
Hu, Peng [1 ,2 ]
Yeon, Susan B. [1 ,2 ]
Kissinger, Kraig V. [1 ,2 ]
Goddu, Beth [1 ,2 ]
Goepfert, Lois [1 ,2 ]
Manning, Warren J. [1 ,2 ,4 ]
Kozerke, Sebastian [3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
3D SSFP whole-heart MRI; coronary vein imaging; magnetization transfer contrast; CARDIAC RESYNCHRONIZATION; RESONANCE ANGIOGRAPHY; CONTRAST-AGENT; BALANCED SSFP; MINUTES; FAILURE; SYSTEM; TISSUE; TIME;
D O I
10.1002/jmri.21788
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare two coronary vein imaging techniques using whole-heart balanced steady-state free precession (SSFP) and a targeted double-oblique spoiled gradient-echo (GRE) sequences in combination with magnetization transfer (MT) preparation sequence for tissue contrast. improvement. Materials and Methods: Nine healthy subjects were imaged with the proposed technique. The results are compared with optimized targeted MT prepared GRE acquisitions. Both quantitative and qualitative analyses were performed to evaluate each imaging method. Results: Whole-heart images were successfully acquired with no visible image artifact in the vicinity of the coronary veins. The anatomical features and Visual grading of both techniques were comparable. However, the targeted small slab acquisition of the left ventricular lateral wall was superior to whole-heart acquisition for visualization of relevant information for cardiac resynchronization therapy (CRT) lead implantation. Conclusion: We demonstrated the feasibility of whole-heart coronary vein MRI using a 3D MT-SSFP imaging sequence. A targeted acquisition along the lateral left ventricular wall is preferred for visualization of branches commonly used in CRT lead implantation.
引用
收藏
页码:1293 / 1299
页数:7
相关论文
共 22 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]  
BALABAN R S, 1992, Magnetic Resonance Quarterly, V8, P116
[3]   Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent [J].
Bi, Xiaoming ;
Carr, James C. ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (01) :1-7
[4]   Effect of posterolateral scar tissue on clinical and echocardiographic improvement after cardiac resynchronization therapy [J].
Bleeker, GB ;
Kaandorp, TAM ;
Lamb, HJ ;
Boersma, E ;
Steendijk, P ;
de Roos, A ;
van der Wall, EE ;
Schalij, MJ ;
Bax, JJ .
CIRCULATION, 2006, 113 (07) :969-976
[5]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[6]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[7]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[8]  
2-9
[9]   Quantitative magnetization transfer imaging using balanced SSFP [J].
Gloor, M. ;
Scheffler, K. ;
Bieri, O. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :691-700
[10]   Free-breathing whole-heart coronary MR angiography on a clinical scanner in four minutes [J].
Nehrke, K ;
Börnert, P ;
Mazurkewitz, P ;
Winkelmann, R ;
Grässlin, I .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) :752-756