Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent

被引:87
作者
Bi, Xiaoming
Carr, James C.
Li, Debiao
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
magnetic resonance imaging; magnetic resonance angiography; coronary arteries; 3; Tesla; contrast media;
D O I
10.1002/mrm.21224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
T-1-shortening contrast agents have been used to improve the depiction of coronary arteries with breath-hold magnetic resonance angiography (MRA). The spatial resolution and coverage are limited by the duration of the arterial phase of the contrast media passage. In this study we investigated the feasibility of acquiring free-breathing, whole-heart coronary MRA during slow infusion of the contrast media (0.3 ml/s) for prolonged blood signal enhancement time. Ultrashort TR (3 ms) and parallel data acquisition were used to allow the whole-heart MRA in approximately 5 min. A newly approved gadolinium (Gd)-based high T-1 relaxivity contrast agent, gadobenate dimeglumine ([Gd-BOPTA](2-)), was used and coronary MRA was performed on a whole-body 3 Tesla M system to improve the signal-to-noise ratio (SNR). Results from eight volunteers demonstrate that this coronary MRA method is capable of imaging the whole heart in 4.5 +/- 0.6 min. Major coronary arteries are well depicted with high SNR (42.4 +/- 12.5) and contrast-to-noise ratio (CNR; 27.1 +/- 7.6). Magn Reson Med 58:1-7, 2007. (c) 2007 Wiley-Liss, Inc.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 28 条
[1]  
Aharon S, 2006, P 14 ANN M ISMRM SEA
[2]  
BI X, 2005, P 13 ANN M ISMRM MIA
[3]   Three-dimensional breathhold SSFP coronary MRA: A comparison between 1.5T and 3.OT [J].
Bi, XM ;
Deshpande, V ;
Simonetti, O ;
Laub, G ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) :206-212
[4]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[5]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[6]   Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency [J].
Deshpande, VS ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :803-809
[7]   Starter sequence for steady-state free precession imaging [J].
Foxall, DL .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) :919-929
[8]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[9]   Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA [J].
Huber, ME ;
Paetsch, I ;
Schnackenburg, B ;
Bornstedt, A ;
Nagel, E ;
Fleck, E ;
Boesiger, P ;
Maggioni, F ;
Cavagna, FM ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :115-121
[10]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869