Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT

被引:103
作者
Kopp, AF
Ohnesorge, B
Becker, C
Schröder, S
Heuschmid, M
Küttner, A
Kuzo, R
Claussen, CD
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Cardiol, D-72076 Tubingen, Germany
[3] Siemens Med Engn, CT Div, Forchheim, Germany
[4] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-8000 Munich, Germany
[5] Mayo Clin Jacksonville, Dept Radiol, Jacksonville, FL 32224 USA
关键词
experimental study; heart; calcification; CT; phantoms;
D O I
10.1148/radiol.2251010173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To methodically evaluate the reproducibility and accuracy of coronary arterial calcification measurements by using spiral multi-detector row and electron-beam computed tomography (CT) with a beating heart phantom. MATERIALS AND METHODS: A phantom was built to mimic a beating heart with coronary arteries and calcified plaques. The simulated vessels moved in a pattern similar to that of a beating heart. The phantom operated at a variety of pulse rates (0-140 beats per minute). The phantom was repeatedly scanned in various positions by using various protocols with electron-beam and multi-detector row CT scanners to assess interexamination variability. Statistical analysis was performed to determine significant differences in interexamination variability for various acquisition protocols. RESULTS: Electrocardiographically (EKG) gated volume coverage with spiral multi-detector row CT (2.5-mm collimation) and overlapping image reconstruction (1-mm increment) was found to significantly improve the reliability of coronary arterial calcium quantification, especially for small plaques (P < .05). Mean interexamination variability was reduced from 35% +/- 6 (SD) (Agatston score, standard electron-beam CT) to 4% +/- 2 (P < .05) (volumetric score, spiral EKG-gated multi-detector row CT). CONCLUSION: By coupling retrospective gating with nearly isotropic volumetric imaging data, spiral multi-detector row CT provides better input data for quantification of coronary arterial calcium volume. Multi-detector row CT allows precise and repeated measurement of coronary arterial calcification, with low interexamination variability. (C) RSNA, 2002.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 17 条
  • [1] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [2] SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE
    BIELAK, LF
    KAUFMANN, RB
    MOLL, PP
    MCCOLLOUGH, CH
    SCHWARTZ, RS
    SHEEDY, PF
    [J]. RADIOLOGY, 1994, 192 (03) : 631 - 636
  • [3] Measurement of coronary artery calcium with dual-slice helical CT compared with coronary angiography: Evaluation of CT scoring methods, interobserver variations, and reproducibility
    Broderick, LS
    Shemesh, J
    Wilensky, RL
    Eckert, GJ
    Zhou, XH
    Torres, WE
    Balk, MA
    Rogers, WJ
    Conces, DJ
    Kopecky, KK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 439 - 444
  • [4] Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    Callister, TQ
    Cooil, B
    Raya, SP
    Lippolis, NJ
    Russo, DJ
    Raggi, P
    [J]. RADIOLOGY, 1998, 208 (03) : 807 - 814
  • [5] REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY
    DEVRIES, S
    WOLFKIEL, C
    SHAH, V
    CHOMKA, E
    RICH, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) : 973 - 975
  • [6] Coronary arterial calcium screening: Ready for prime time
    Flamm, SD
    [J]. RADIOLOGY, 1998, 208 (03) : 571 - 572
  • [7] Hernigou A, 1996, EUR RADIOL, V6, P210
  • [8] DETECTION AND QUANTITATION OF CALCIFIC ATHEROSCLEROSIS BY ULTRAFAST COMPUTED-TOMOGRAPHY IN CHILDREN AND YOUNG-ADULTS WITH HOMOZYGOUS FAMILIAL HYPERCHOLESTEROLEMIA
    HOEG, JM
    FEUERSTEIN, IM
    TUCKER, EE
    [J]. ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (07): : 1066 - 1074
  • [9] QUANTIFICATION OF CORONARY-ARTERY CALCIFICATION USING ULTRAFAST COMPUTED-TOMOGRAPHY - REPRODUCIBILITY OF MEASUREMENTS
    KAJINAMI, K
    SEKI, H
    TAKEKOSHI, N
    MABUCHI, H
    [J]. CORONARY ARTERY DISEASE, 1993, 4 (12) : 1103 - 1108
  • [10] Subsecond multi-slice computed tomography: basics and applications
    Klingenbeck-Regn, K
    Schaller, S
    Flohr, T
    Ohnesorge, B
    Kopp, AF
    Baum, U
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) : 110 - 124