End-column amperometric detection of aesculin and aesculetin by capillary electrophoresis

被引:25
作者
You, TY
Yang, XR
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, Electroanalyt Chem Lab, Changchun 130022, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, Natl Analyt Res Ctr Electrochem & Spect, Changchun 130022, Peoples R China
基金
中国国家自然科学基金;
关键词
end-column; amperometic detection; aesculin (AL); aesculetin (AT); capillary electrophoresis (CE);
D O I
10.1016/S0003-2670(99)00497-3
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Determination of aesculin (AL) and aesculetin (AT) by capillary electrophoresis with end-column amperometric detection using a 33 mu m microdisk carbon fiber electrode is described. The HDVs, the effect of pH, buffer concentration, injection voltage, injection time and separation voltage on the peak current response (i(p)) of the analytes and the number of theoretical plates (N) were studied. The method has high sensitivity and good reproducibility. Under the optimum condition - 10 mM, pH 9.00 phosphate buffer, 4 s at 9 kV injection, separation at 15 kV and +1.0 V as the detection potential - low detection limits (S/N = 3) of 0.06 and 0.3 mu M were obtained for AL and AT, respectively. The calibration curve was linear over three orders of magnitude. The relative standard deviations (n = 15) of peak current and migration time were 3.9% and 4.6%, and 0.96% and 0.75% for 15 consecutive injections of 5 mu M AL and AT, respectively. The use of this method for the separation and detection of the two compounds present in the traditional Chinese medicine and human urine samples is also reported. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 24 条
[1]
CAPILLARY ELECTROPHORESIS WITH AMPEROMETRIC DETECTION USING A POROUS CELLULOSE-ACETATE JOINT [J].
CHEN, IC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :208-212
[2]
COPPER WIRE AMPEROMETRIC DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
ENGSTROMSILVERMAN, CE ;
EWING, AG .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (02) :141-145
[3]
GUO XS, 1983, ACTA PHARMACOL SINIC, V18, P446
[4]
END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[5]
BIAS IN QUANTITATIVE CAPILLARY ZONE ELECTROPHORESIS CAUSED BY ELECTROKINETIC SAMPLE INJECTION [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :375-377
[6]
DETERMINATION OF THIOLS BY CAPILLARY ELECTROPHORESIS WITH ELECTROCHEMICAL DETECTION USING A PALLADIUM FIELD-DECOUPLER AND CHEMICALLY-MODIFIED ELECTRODES [J].
HUANG, XJ ;
KOK, WT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :347-353
[7]
CAPILLARY ZONE ELECTROPHORESIS [J].
JORGENSON, JW ;
LUKACS, KD .
SCIENCE, 1983, 222 (4621) :266-272
[8]
SOLID-STATE FIELD DECOUPLER FOR OFF-COLUMN DETECTION IN CAPILLARY ELECTROPHORESIS [J].
KOK, WT ;
SAHIN, Y .
ANALYTICAL CHEMISTRY, 1993, 65 (18) :2497-2501
[9]
LI G, 1995, CHINESE J ANAL CHEM, V123, P480
[10]
LIU Z, 1998, CHINESE J ANAL CHEM, V6, P786