A lactulose bienzyme biosensor based on self-assembled monolayer modified electrodes

被引:12
作者
Campuzano, S [1 ]
Pedrero, M [1 ]
de Villena, FJM [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac CC Quim, Dept Quim Analit, E-28040 Madrid, Spain
关键词
self-assembled monolayers; enzyme electrodes; lactulose; milk;
D O I
10.1002/elan.200402983
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bienzyme biosensor in which the enzymes beta-galactosidase (beta-Gal), fructose dehydrogenase (FDH), and the mediator tetrathiafulvalene (TTF) were coimmobilized by cross-linking with glutaraldehyde atop a 3-mercaptopropionic acid (MPA) self-assembled monolayer on a gold disk electrode, is reported. The working conditions selected were E-app = + 0.10 V and (25 +/- 1)degreesC. The useful lifetime of one single TTF-beta-Gal-FDH-MPA-AuE was surprisingly long, 81 days. A linear calibration plot was obtained for lactulose over the 3.0 x 10(-5) - 1.0 x 10(-3) mol L-1 concentration range, with a limit of detection of 9.6 x 10(-6) mol L-1. The effect of potential interferents (lactose, glucose, galactose, sucrose, and ascorbic acid) on the biosensor response was evaluated. The behavior of the SAM-based biosensor in flow-injection systems in connection with amperometric detection was tested. The analytical usefulness of the biosensor was evaluated by determining lactulose in a pharmaceutical preparation containing a high lactulose concentration, and in different types of milk. Finally, the analytical characteristics of the TTF-beta-Gal-FDH-MPA-AuE are critically compared with those reported for other recent enzymatic determinations of lactulose.
引用
收藏
页码:1385 / 1392
页数:8
相关论文
共 16 条
[1]   A new enzymatic spectrophotometric assay for the determination of lactulose in milk [J].
Amine, A ;
Moscone, D ;
Bernardo, RA ;
Marconi, E ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 2000, 406 (02) :217-224
[2]   FORMATION AND OCCURRENCE OF LACTULOSE IN HEATED MILK [J].
ANDREWS, GR .
JOURNAL OF DAIRY RESEARCH, 1986, 53 (04) :665-680
[3]   NEW ELECTROCATALYTIC BIOMOLECULAR INTERFACE FOR FABRICATING A FRUCTOSE DEHYDROGENASE-BASED SENSING SYSTEM [J].
BEGUM, A ;
KOBATAKE, E ;
SUZAWA, T ;
IKARIYAMA, Y ;
AIZAWA, M .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :31-36
[4]   An integrated electrochemical fructose biosensor based on tetrathiafulvalene-modified self-assembled monolayers on gold electrodes [J].
Campuzano, S ;
Gaálvez, R ;
Pedrero, M ;
Manuel de Villena, FJ ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) :600-607
[5]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[6]  
DeRafael D, 1996, MILCHWISSENSCHAFT, V51, P552
[7]  
*EC, 1992, VI572692
[8]   ENZYMATIC DETERMINATION OF LACTULOSE [J].
GEIER, H ;
KLOSTERMEYER, H .
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1980, 171 (06) :443-445
[9]   Automated determination of lactulose in milk using an enzyme reactor and flow analysis with integrated dialysis [J].
Mayer, M ;
Genrich, M ;
Kunnecke, W ;
Bilitewski, U .
ANALYTICA CHIMICA ACTA, 1996, 324 (01) :37-45
[10]   Rapid determination of lactulose in milk by microdialysis and biosensors [J].
Moscone, D ;
Bernardo, RA ;
Marconi, E ;
Amine, A ;
Palleschi, G .
ANALYST, 1999, 124 (03) :325-329