A confirmatory method for the determination of tetracyclines in muscle using high-performance liquid chromatography with diode-array detection

被引:45
作者
Cristofani, Elisa [1 ]
Antonini, Chiara [1 ]
Tovo, Gloria [1 ]
Fioroni, Laura [1 ]
Piersanti, Arianna [1 ]
Galarini, Roberta [1 ]
机构
[1] Ist Zooprofilattico Sperimentale Umbria & Marche, I-06126 Perugia, Italy
关键词
Tetracyclines; 4-Epimers; Muscle; High-performance liquid chromatography-diode-array detection; Validation; Commission Decision 2002/657/EC; CHELATE AFFINITY-CHROMATOGRAPHY; ANIMAL-TISSUES; MASS-SPECTROMETRY; RESIDUE ANALYSIS; MILK; CHLORTETRACYCLINE; OXYTETRACYCLINE; ANTIBIOTICS; VALIDATION; HPLC;
D O I
10.1016/j.aca.2008.10.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using high-performance liquid chromatography with diode-array detection (HPLC-DAD) technique, a confirmatory method for the determination of trace levels of tetracyclines (oxytetracycline, tetracycline, chlortetracycline and doxycycline) and their 4-epimers (4-epioxytetracycline, 4-epitetracycline and 4-epichlortetracycline) in animal tissues (muscle) was developed. The samples are extracted with a mixture of succinic acid 0.1 M (pH 4) and methanol after the addition of metacycline as internal standard. The clean-up is carried out by metal chelate affinity chromatography with a following concentration step on an OASIS HLB polymeric reversed phase column. The chromatographic separation of the seven analytes is achieved in 10 min on a short monolithic column (50 mm x 4.6 mm i.d.) using a gradient elution. The method was validated in bovine muscle following the Commission Decision 2002/657/EC criteria: samples spiked at four concentration levels (0.25, 0.5, 1 and 1.5 times the maximum residue limit) were analysed. Method trueness and precision (repeatability and intra-laboratory reproducibility) as well as decision limits (CC alpha) and detection capabilities (CC beta) are reported. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 21 条
[1]  
ANDERSEN WE, 2004, EUR 5 P, P269
[2]  
[Anonymous], 2002, Off. J. Eur. Comm, VL221, P8
[3]  
[Anonymous], 1990, OFF J EUR COMMUN L, VL224, P1
[4]   Use of the terms "recovery" and "apparent recovery" in analytical procedures - (IUPAC recommendations 2002) [J].
Burns, DT ;
Danzer, K ;
Townshend, A .
PURE AND APPLIED CHEMISTRY, 2002, 74 (11) :2201-2205
[5]   Reversed-phase high-performance liquid chromatography coupled to ultraviolet and electrospray time-of-flight mass spectrometry on-line detection for the separation of eight tetracyclines in honey samples [J].
Carrasco-Pancorbo, A. ;
Casado-Terrones, S. ;
Segura-Carretero, A. ;
Fernandez-Gutierrez, A. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1195 (1-2) :107-116
[6]   Confirmation of multiple tetracycline residues in milk and oxytetracycline in shrimp by liquid chromatography particle beam mass spectrometry [J].
Carson, MC ;
Ngoh, MA ;
Hadley, SW .
JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2) :113-128
[7]  
CARSON MC, 1993, J AOAC INT, V76, P329
[8]   HPLC determination of tetracyclines in lamb muscle using an RP-C18 monolithic type column [J].
Castellari, M ;
García-Regueiro, JA .
CHROMATOGRAPHIA, 2003, 58 (11-12) :789-792
[9]   Quantitative multi-residue analysis of tetracyclines and their 4-epimers in pig tissues by high-performance liquid chromatography combined with positive-ion electrospray ionization mass spectrometry [J].
Cherlet, M ;
Schelkens, M ;
Croubels, S ;
De Backer, P .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :199-213
[10]   Validation of a high-performance liquid chromatography method for the determination of oxytetracycline, tetracycline, chlortetracycline and doxycycline in bovine milk and muscle [J].
Cinquina, AL ;
Longo, F ;
Anastasi, G ;
Giannetti, L ;
Cozzani, R .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :227-233