X-ray scatter correction algorithm for cone beam CT imaging

被引:290
作者
Ning, R
Tang, XY
Conover, D
机构
[1] Univ Rochester, Dept Radiol, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14642 USA
关键词
scatter; scatter correction; antiscatter grid; cone beam reconstruction; flat panel detector; cone beam CT;
D O I
10.1118/1.1711475
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Developing and optimizing an x-ray scatter control and reduction technique is one of the major challenges for cone beam computed tomography (CBCT) because CBCT will be much less immune to scatter than fan-beam CT. X-ray scatter reduces image contrast, increases image noise and introduces reconstruction error into CBCT. To reduce scatter interference, a practical algorithm that is based upon the beam stop array technique and image sequence processing has been developed on a flat panel detector-based CBCT prototype scanner. This paper presents a beam stop array-based scatter correction algorithm and the evaluation results through phantom studies. The results indicate that the beam stop array-based scatter correction algorithm is practical and effective to reduce and correct x-ray scatter for a CBCT imaging task. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:1195 / 1202
页数:8
相关论文
共 43 条
[1]   Cone-beam volume CT breast imaging: wavelet analysis-based multi-resolution reconstruction and de-noising technique [J].
Chen, B ;
Ning, R .
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 :236-244
[2]   Cone-beam volume CT breast imaging: Feasibility study [J].
Chen, B ;
Ning, R .
MEDICAL PHYSICS, 2002, 29 (05) :755-770
[3]  
CONOVER D, 2003, P SOC PHOTO-OPT INS, V5030, P768
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   SCATTER COMPENSATION FOR DIGITAL CHEST RADIOGRAPHY USING MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATION [J].
FLOYD, CE ;
BAYDUSH, AH ;
LO, JY ;
BOWSHER, JE ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1993, 28 (05) :427-433
[6]   COMPTON SCATTER EFFECTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH .
MEDICAL PHYSICS, 1982, 9 (06) :860-867
[7]   Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[8]  
JAFFRAY DA, 1999, P SOC PHOTO-OPT INS, V3569, P215
[9]   SCATTERED RADIATION IN FAN BEAM IMAGING-SYSTEMS [J].
JOHNS, PC ;
YAFFE, M .
MEDICAL PHYSICS, 1982, 9 (02) :231-239
[10]   Feldkamp and circle-and-line cone-beam reconstruction for 3D micro-CT of vascular networks [J].
Johnson, RH ;
Hu, H ;
Haworth, ST ;
Cho, PS ;
Dawson, CA ;
Linehan, JH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :929-940