High-resolution imaging reveals a limit in spatial resolution of blood flow measurements by microspheres

被引:28
作者
Decking, UKM
Pai, VM
Bennett, E
Taylor, JL
Fingas, CD
Zanger, K
Wen, H
Balaban, RS
机构
[1] Univ Dusseldorf, Dept Cardiovasc Physiol, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Inst Anat 2, D-40225 Dusseldorf, Germany
[3] NHLBI, Lab Cardiac Energet, NIH, Bethesda, MD 20892 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2004年 / 287卷 / 03期
关键词
myocardial perfusion; microscopy; fluorescence; magnetic resonance; iron oxide particle;
D O I
10.1152/ajpheart.00119.2004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Density of 15-mum microspheres after left atrial application is the standard measure of regional perfusion. In the heart, substantial differences in microsphere density are seen at spatial resolutions <5 ml, implying perfusion heterogeneity. Microsphere deposition imaging permits a superior evaluation of the distribution pattern. Therefore, fluorescent microspheres (FMS) were applied, FMS deposition in the canine heart was imaged by epifluorescence microscopy in vitro, and the patterns were observed compared with MR images of iron oxide microspheres (IMS) obtained in vivo and in vitro. FMS deposition in myocardial slices revealed the following: 1) a nonrandom distribution, with sequentially applied FMS of different color stacked within the same vessel, 2) general FMS clustering, and 3) rather large areas devoid of FMS (n = 3). This pattern was also seen in reconstructed three-dimensional images (<1 nl resolution) of FMS distribution ( n = 4). Surprisingly, the deposition pattern of sequentially applied FMS remained virtually identical over 3 days. Augmenting flow by intracoronary adenosine ( >2 muM) enhanced local microsphere density, but did not alter the deposition pattern ( n = 3). The nonrandom, temporally stable pattern was quantitatively confirmed by a three-dimensional intermicrosphere distance analysis of sequentially applied FMS. T-2-weighted short-axis MR images (2-mul resolution) of IMS revealed similar patterns in vivo and in vitro ( n = 6), as seen with FMS. The observed temporally stable microsphere patterns are not consistent with the notion that microsphere deposition is solely governed by blood flow. We propose that at high spatial resolution (<2 mu l) structural aspects of the vascular network dominate microsphere distribution, resulting in the organized patterns observed.
引用
收藏
页码:H1132 / H1140
页数:9
相关论文
共 28 条
  • [1] Function, metabolic, and flow heterogeneity of the heart - The view is getting better
    Balaban, RS
    Arai, A
    [J]. CIRCULATION RESEARCH, 2001, 88 (03) : 265 - 267
  • [2] VALIDITY OF MICROSPHERE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS
    BASSINGTHWAIGHTE, JB
    MALONE, MA
    MOFFETT, TC
    KING, RB
    LITTLE, SE
    LINK, JM
    KROHN, KA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (01): : H184 - H193
  • [3] FRACTAL NATURE OF REGIONAL MYOCARDIAL BLOOD-FLOW HETEROGENEITY
    BASSINGTHWAIGHTE, JB
    KING, RB
    ROGER, SA
    [J]. CIRCULATION RESEARCH, 1989, 65 (03) : 578 - 590
  • [4] MOLECULAR AND PARTICULATE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS IN SHEEP
    BASSINGTHWAIGHTE, JB
    MALONE, MA
    MOFFETT, TC
    KING, RB
    CHAN, IS
    LINK, JM
    KROHN, KA
    [J]. CIRCULATION RESEARCH, 1990, 66 (05) : 1328 - 1344
  • [5] High spatial resolution measurements of organ blood flow in small laboratory animals
    Bernard, SL
    Ewen, JR
    Barlow, CH
    Kelly, JJ
    McKinney, S
    Frazer, DA
    Glenny, RW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (05): : H2043 - H2052
  • [6] SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES
    BUCKBERG, GD
    LUCK, JC
    PAYNE, DB
    HOFFMAN, JIE
    ARCHIE, JP
    FIXLER, DE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) : 598 - &
  • [7] MODEL STUDIES ON DISTRIBUTION OF BLOOD-CELLS AT MICROVASCULAR BIFURCATIONS
    CHIEN, S
    TVETENSTRAND, CD
    EPSTEIN, MAF
    SCHMIDSCHONBEIN, GW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 248 (04): : H568 - H576
  • [8] COLORED MICROSPHERES REVEAL INTERARTERIAL MICROVASCULAR ANASTOMOSES IN CANINE MYOCARDIUM
    CICUTTI, N
    RAKUSAN, K
    DOWNEY, HF
    [J]. BASIC RESEARCH IN CARDIOLOGY, 1992, 87 (04) : 400 - 409
  • [9] Spatial heterogeneity in the heart: Recent insights and open questions
    Decking, UKM
    [J]. NEWS IN PHYSIOLOGICAL SCIENCES, 2002, 17 : 246 - 250
  • [10] Spatial heterogeneity of energy turnover in the heart
    Decking, UKM
    Skwirba, S
    Zimmermann, MF
    Preckel, B
    Thämer, V
    Deussen, A
    Schrader, J
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2001, 441 (05): : 663 - 673