A novel electrode array for diameter-dependent control of axonal excitability: A simulation study

被引:20
作者
Lertmanorat, Z [1 ]
Durand, DM [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Neural Engn Ctr, Cleveland, OH 44106 USA
关键词
neural prostheses; recruitment order; selective neural stimulation;
D O I
10.1109/TBME.2004.827347
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrical extracellular stimulation of peripheral nerve activates the large-diameter motor fibers before the small ones, a recruitment order opposite the physiological recruitment of myelinated motor fibers during voluntary muscle contraction. Current methods to solve this problem require a long-duration stimulus pulse which could lead to electrode corrosion and nerve damage. The hypothesis that the excitability of specific diameter fibers can be suppressed by reshaping the profile of extracellular potential along the axon using multiple electrodes is tested using computer simulations in two different volume conductors. Simulations in a homogenous medium with a nine-contact electrode array show that the current excitation threshold (I-th) of large diameter axons (13-17 mum) (0.6-3.0 mA) is higher than that of small-diameter axons (2-7 mum) (0.4-0.7 mA) with 200-mum axon-electrode distance and 10-mus stimulus pulse. The electrode array is also tested in a three-dimensional finite-element model of the sacral root model of dog (ventral root of S3). A single cathode activates large-diameter axons before activating small axons. However, a nine-electrode array activates 50% of small axons while recruiting only 10% of large ones and activates 90% of small axons while recruiting only 50% of large ones. The simulations suggest that the near-physiological recruitment order can be achieved with an electrode array. The diameter selectivity of the electrode array can be controlled by the electrode separation and the method is independent of pulse width.
引用
收藏
页码:1242 / 1250
页数:9
相关论文
共 29 条
[1]   Selective suppression of sphincter activation during sacral anterior nerve root stimulation [J].
Bhadra, N ;
Grünewald, V ;
Creasey, G ;
Mortimer, JT .
NEUROUROLOGY AND URODYNAMICS, 2002, 21 (01) :55-64
[2]   ACUTE AND CHRONIC IMPLANTATION OF COILED WIRE INTRANEURAL ELECTRODES DURING CYCLICAL ELECTRICAL-STIMULATION [J].
BOWMAN, BR ;
ERICKSON, RC .
ANNALS OF BIOMEDICAL ENGINEERING, 1985, 13 (01) :75-93
[3]   PERCUTANEOUS WIRE ELECTRODE FOR CHRONIC RESEARCH USE [J].
CALDWELL, CW ;
RESWICK, JB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, 22 (05) :429-432
[4]   The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model [J].
Deurloo, KEI ;
Holsheimer, J ;
Bergveld, P .
BIOLOGICAL CYBERNETICS, 2001, 85 (04) :281-291
[5]   A METHOD TO EFFECT PHYSIOLOGICAL RECRUITMENT ORDER IN ELECTRICALLY ACTIVATED MUSCLE [J].
FANG, ZP ;
MORTIMER, JT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (02) :175-179
[6]   SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&
[7]   RECRUITMENT PROPERTIES OF MONOPOLAR AND BIPOLAR EPIMYSIAL ELECTRODES [J].
GRANDJEAN, PA ;
MORTIMER, JT .
ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (01) :53-66
[8]   STIMULUS WAVE-FORMS FOR SELECTIVE NEURAL STIMULATION [J].
GRILL, WM ;
MORTIMER, JT .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (04) :375-385
[9]   Conduction velocity and diameter of nerve fibers [J].
Hursh, JB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1939, 127 (01) :131-139
[10]   SELECTIVE SACRAL ROOT STIMULATION FOR BLADDER CONTROL - ACUTE EXPERIMENTS IN AN ANIMAL-MODEL [J].
KOLDEWIJN, EL ;
RIJKHOFF, NJM ;
VANKERREBROECK, PEV ;
DEBRUYNE, FMJ ;
WIJKSTRA, H .
JOURNAL OF UROLOGY, 1994, 151 (06) :1674-1679