Biological qualification of blood units - Considerations about the effects of sample's handling and storage on stability of nucleic acids

被引:26
作者
Gessoni, G [1 ]
Barin, P [1 ]
Valverde, S [1 ]
Giacomini, A [1 ]
Di Natale, C [1 ]
Orlandini, E [1 ]
Arreghini, N [1 ]
De Fusco, G [1 ]
Frigato, A [1 ]
Fezzi, M [1 ]
Antico, F [1 ]
Marchiori, G [1 ]
机构
[1] Osped Civile, Dept Clin Pathol, Reg Veneto, AULS Chioggia 14, I-30015 Chioggia, VE, Italy
关键词
HBV-DNA; HCV-RNA; HIV-RNA; stability; storage; biological qualification; detection-limit;
D O I
10.1016/j.transci.2003.11.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In transfusional setting introduction of nucleic amplification technique (NAT) for HBV-DNA, HCV-RNA and HIV-RNA in biological qualification of blood units suggest some problems. At first the opportunity to operate on mini-pool, at second the need to store the samples at +4 degreesC. The authors therefore have tried to estimate the impact of these conditions on the operativity of NAT testing in the transfusional setting. Methods: The following parameters has been estimated: distribution of viral-load in untreated subjects, stability of nucleic acids during storage at +4 degreesC, stability of nucleic acids after repeated cycles of freezing and defrosting, robustness of the test to the cross-contamination, definition of the detection-limit (95%). Quantitative tests has been performed by using the following kits: Cobas Amplicor HBV Monitor, Cobas Amplicor HCV Monitor, Cobas Amplicor HIV Monitor; the qualitative tests has been performed by using the following kits: Ampliscreen HBV, Ampliscreen HCV 2,0, Ampliscreen HIV 1,5 all supplied by Roche Molecular System (Brancburg, NJ). Results: Viral load in untreated subjects showed wide variation for HBV, HCV and HIV. HBV has been demonstrated much stable to the conservation +4 degreesC also until 168 h while for HCV and HIV a greater decrease of the viral-load was observed. For all and three virus the conservation to +4 degreesC until 72 It does not seem to involve meaningful fall in the viral-load. A remarkable reduction of the viral-load has been observed after five cycles of freezing and defrosting. All the tests showed a good robustness to cross-contamination. The detection-limit (95%) was 8 U/ml for HBV, 21 U/ml for HCV and 27 copy/ml for HIV. Conclusions: Samples for NAT testing, can be stored until 72 h to +4 degreesC without appreciable lowering of the viral-load. Repeated cycles of changes of state should be avoided. The tests showed a good robustness to cross-contamination. NAT tests for biological qualification of blood units had a minimal sensibility around 50 (copy/unit/ml). In our experience the detection-limit (95%) was 21 U/ml for HCV, 27copies/ml for HIV, 8 U/ml for HBV. The availability of NAT test for HBV-DNA, HCV-RNA e HIV-RNA, sensitive and reliable, together with epidemiological data, suggest the opportunity to place side by side, in the biological qualification of the blood units, to add the tests for HBV-DNA and HIV-RNA to the test for HCV-RNA mandatory by low, in Italy in the biological qualification of blood units. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 39 条
  • [31] Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA
    Stelzl, E
    Kormann-Klement, A
    Haas, J
    Daghofer, E
    Santner, BI
    Marth, E
    Kessler, HH
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (04) : 1447 - 1450
  • [32] Simultaneous extraction of hepatitis C virus (HCV),hepatitis B virus, and HIV-1 from plasma and detection of HCV RNA by a reverse transcriptase-polymerase chain reaction assay designed for screening pooled units of donated blood
    Sun, R
    Schilling, W
    Jayakar, H
    Ku, J
    Wang, J
    Rosenstraus, M
    Spadoro, J
    [J]. TRANSFUSION, 1999, 39 (10) : 1111 - 1119
  • [33] Sun R, 2000, Dev Biol (Basel), V102, P81
  • [34] Residual risk of transfusion-transmitted HCV and HIV infections by antibody-screened blood in Italy
    Velati, C
    Romanò, L
    Baruffi, L
    Pappalettera, M
    Carreri, V
    Zanetti, AR
    [J]. TRANSFUSION, 2002, 42 (08) : 989 - 993
  • [35] Mathematic modeling of the risk of HBV, HCV, and HIV transmission by window-phase donations not detected by NAT
    Weusten, JJAM
    van Drimmelen, HAJ
    Lelie, PN
    [J]. TRANSFUSION, 2002, 42 (05) : 537 - 548
  • [36] Kinetics of acute hepatitis B virus infection in humans
    Whalley, SA
    Murray, JM
    Brown, D
    Webster, GJM
    Emery, VC
    Dusheiko, GM
    Perelson, AS
    [J]. JOURNAL OF EXPERIMENTAL MEDICINE, 2001, 193 (07) : 847 - 853
  • [37] Performance characteristics of the COBAS AmpliScreen HIV-1 test, version 1.5, an assay designed for screening plasma mini-pools
    Yang, YF
    Lamendola, MN
    Mendoza, M
    Xu, D
    Nguyen, M
    Yeh, S
    Wu, YQ
    Ku, J
    Rosenstraus, M
    Sun, R
    [J]. TRANSFUSION, 2001, 41 (05) : 643 - 651
  • [38] 1996, EUROPEAN PHARMACOPEI
  • [39] 1999, DECRETO MINISTERO IT