Accuracy of Postoperative End-tidal PCO2 Measurements with Mainstream and Sidestream Capnography in Non-obese Patients and in Obese Patients with and without Obstructive Sleep Apnea

被引:65
作者
Kasuya, Yusuke
Akca, Ozan
Sessler, Daniel I. [1 ]
Ozaki, Makoto
Komatsu, Ryu
机构
[1] Cleveland Clin, Dept Outcomes Res, Cleveland, OH 44195 USA
关键词
CARBON-DIOXIDE; ANESTHESIA; ARTERIAL; CHILDREN; OXYGEN;
D O I
10.1097/ALN.0b013e3181b060b6
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background: Obtaining accurate end-tidal carbon dioxide pressure measurements via nasal cannula poses difficulties in postanesthesia patients who are mouth breathers, including those who are obese and those with obstructive sleep apnea (OSA); a nasal cannula with an oral guide may improve measurement accuracy in these patients. The authors, evaluated the accuracy of a mainstream capnometer with an oral guide nasal cannula and a sidestream capnometer with a nasal cannula that did or did not incorporate an oral guide in spontaneously breathing non-obese patients and obese patients with and without OSA during recovery from general anesthesia. Methods: The study enrolled 20 non-obese patients (body mass index less than 30 kg/m(2)) without OSA, 20 obese patients (body mass index greater than 35 kg/m(2)) without OSA, and 20 obese patients with OSA. End-tidal carbon dioxide pressure was measured by using three capnometer/cannula combinations (oxygen at 4 l/min): (1) a mainstream capnometer with oral guide nasal cannula, (2) a sidestream capnometer with a nasal carmula that included an oral guide, and (3) a sidestream capnometer with a standard nasal cannula. Arterial carbon dioxide partial pressure was determined simultaneously. The major outcome was the arterial-to-end-tidal partial pressure difference with each combination. Results: In non-obese patients, arterial-to-end-tidal pressure difference was 3.0 +/- 2.6 (mean +/- SD) mmHg with the mainstream capnometer, 4.9 +/- 2.3 mmHg with the sidestream capnometer and oral guide cannula, and 7.1 +/- 3.5 mmHg with the sidestream capnometer and a standard cannula (P < 0.05). In obese non-OSA patients, it was 3.9 +/- 2.6 mmHg, 6.4 +/- 3.1 nmHg, and 8.1 +/- 5.0 mmHg, respectively (P < 0.05). In obese OSA patients, it was 4.0 +/- 3.1 mmHg, 6.3 +/- 3.2 mmHg, and 8.3 +/- 4.6 mmHg, respectively (P < 0.05). Conclusions: Mainstream capnometry performed best, and an oral guide improved the performance of sidestream capnometry. Accuracy in non-obese and obese patients, with and without OSA, was similar.
引用
收藏
页码:609 / 615
页数:7
相关论文
共 29 条
[1]
Hypercapnia improves tissue oxygenation [J].
Akça, O ;
Doufas, AG ;
Morioka, N ;
Iscoe, S ;
Fisher, J ;
Sessler, DI .
ANESTHESIOLOGY, 2002, 97 (04) :801-806
[2]
[Anonymous], ANESTHESIOL CLIN N A
[3]
TERMINOLOGY AND THE CURRENT LIMITATIONS OF TIME CAPNOGRAPHY - A BRIEF REVIEW [J].
BHAVANISHANKAR, K ;
KUMAR, AY ;
MOSELEY, HSL ;
AHYEEHALLSWORTH, R .
JOURNAL OF CLINICAL MONITORING, 1995, 11 (03) :175-182
[4]
CAPNOMETRY AND ANESTHESIA [J].
BHAVANISHANKAR, K ;
MOSELEY, H ;
KUMAR, AY ;
DELPH, Y .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (06) :617-632
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
ACCURATE DETERMINATION OF END-TIDAL CARBON-DIOXIDE DURING ADMINISTRATION OF OXYGEN BY NASAL CANNULAE [J].
BOWE, EA ;
BOYSEN, PG ;
BROOME, JA ;
KLEIN, EF .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (02) :105-110
[7]
Trends in anesthesia-related death and brain damage - A closed claims analysis [J].
Cheney, Frederick W. ;
Posner, Karen L. ;
Lee, Lorri A. ;
Caplan, Robert A. ;
Domino, Karen B. .
ANESTHESIOLOGY, 2006, 105 (06) :1081-1086
[8]
Microstream capnography technology: A new approach to an old problem [J].
Colman, Y ;
Krauss, B .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (06) :403-409
[9]
OCCUPATIONAL EXPOSURE TO ANESTHETICS IN 20 HOSPITALS [J].
DAVENPORT, HT ;
HALSEY, MJ ;
WARDLEYSMITH, B ;
BATEMAN, PE .
ANAESTHESIA, 1980, 35 (04) :354-359