A sensitive and specific liquid chromatography-tandem mass spectrometry method for the determination of intracellular and extracellular uric acid

被引:66
作者
Kim, Kyung Mee [1 ]
Henderson, George N. [1 ]
Ouyang, Xiaosen [1 ]
Frye, Reginald F. [2 ]
Sautin, Yuri Y. [1 ]
Feig, Daniel I. [3 ]
Johnson, Richard J. [1 ]
机构
[1] Univ Florida, Div Nephrol Hypertens & Transplantat, Dept Med, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Pharm Practice, Coll Pharm, Gainesville, FL 32610 USA
[3] Baylor Coll Med, Dept Pediat, Houston, TX 77030 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 22期
关键词
Uric acid; Urine; Plasma; Cell lysate; Cardiovascular disease; LC-MS/MS; CELL-PROLIFERATION; ASCORBIC ACIDS; SERUM; HYPOXANTHINE; XANTHINE; PLASMA; ALLANTOIN;
D O I
10.1016/j.jchromb.2009.05.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Uric acid (UA) is known to be a major biological antioxidant in plasma. However, there is a strong correlation between UA levels and cardiovascular risk. Recent studies suggest that in the intracellular environment, UA can become a prooxidant that causes endothelial dysfunction. For conducting detailed studies of UA's role in human pathogenesis, there is a critical need for a sensitive and specific method for the determination of intracellular UA levels. We therefore developed a simple, sensitive method for determination of trace amounts of intracellular UA, as well as comparatively large amounts of UA in plasma and urine (for the determination of extracellular concentrations of UA), based on liquid chromatography and tandem mass spectrometry (LC-MS/MS). UA was separated from interferences by HPLC and quantified by mass spectrometry in the negative ESI mode using single reaction monitoring (SRM). For the identification and quantification of UA, the parent ions selected were m/z 167.0, which corresponds to the urate anion, and m/z 169.0, which corresponds to the 1,3-N-15(2)-UA anion. 1,3-N-15(2)-UA is used as an internal standard to ensure accuracy of the measurement. After precipitation of proteins with 10% TCA solution, UA was subjected to LC-MS/MS analysis. The correlation coefficient was 0.9998-1.0000 based on the calibration curve. The intra- and inter-day precision (C.V.%) ranged from 0.01 to 3.07 and 0.01 to 3.68 for in vivo and in vitro systems, respectively. Recovery tests of added standards have been successfully performed and the values ranged from 90.10 to 103.59% and 98.74 to 106.12% for in vivo and in vitro analyses, respectively. This study demonstrates that intracellular levels of UA can be measured using LC-MS/MS with isotope labeled UA as an internal standard. Published by Elsevier B.V.
引用
收藏
页码:2032 / 2038
页数:7
相关论文
共 44 条
[1]   Low plasma uric acid level in Parkinson's disease [J].
Annanmaki, Tua ;
Muuronen, Antti ;
Murros, Kari .
MOVEMENT DISORDERS, 2007, 22 (08) :1133-1137
[2]  
Chen XB, 1998, J MASS SPECTROM, V33, P130, DOI 10.1002/(SICI)1096-9888(199802)33:2<130::AID-JMS616>3.0.CO
[3]  
2-Y
[4]  
CHERNECKY CC, 2001, LAB TESTS DIAGNOSTIC, P1042
[5]   Ketohexokinase-Dependent Metabolism of Fructose Induces Proinflammatory Mediators in Proximal Tubular Cells [J].
Cirillo, Pietro ;
Gersch, Michael S. ;
Mu, Wei ;
Scherer, Philip M. ;
Kim, Kyung Mee ;
Gesualdo, Loreto ;
Henderson, George N. ;
Johnson, Richard J. ;
Sautin, Yuri Y. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 20 (03) :545-553
[6]   METHOD FOR DERIVING NORMAL RANGES FROM LABORATORY SPECIMENS APPLIED TO URIC ACID IN MALES [J].
COOK, MG ;
LEVELL, MJ ;
PAYNE, RB .
JOURNAL OF CLINICAL PATHOLOGY, 1970, 23 (09) :778-&
[7]   Quantification of uric acid, xanthine and hypoxanthine in human serum by HPLC for pharmacodynamic studies [J].
Cooper, Nancy ;
Khosravan, Reza ;
Erdmann, Carol ;
Fiene, John ;
Lee, Jean W. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 837 (1-2) :1-10
[8]   Uric acid stimulates vascular smooth muscle cell proliferation and oxidative stress via the vascular renin-angiotensin system [J].
Corry, Dalila B. ;
Eslami, Pirooz ;
Yamamoto, Kei ;
Nyby, Michael D. ;
Makino, Hirofumi ;
Tuck, Michael L. .
JOURNAL OF HYPERTENSION, 2008, 26 (02) :269-275
[9]   Simultaneous measurement of allantoin, uric acid, xanthine and hypoxanthine in blood by high-performance liquid chromatography [J].
Czauderna, M ;
Kowalczyk, J .
JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2) :89-98
[10]   Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method [J].
Dai, Xinhua ;
Fang, Xiang ;
Zhang, Chunmei ;
Xu, Ruifeng ;
Xu, Bei .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (02) :287-295