Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation

被引:42
作者
Evans, SL
Hunt, CM
Ahuja, S
机构
[1] Cardiff Univ, Sch Engn, Cardiff CF24 0YF, S Glam, Wales
[2] Univ Wales Hosp, Cardiff CF14 4XY, S Glam, Wales
关键词
Pedicle Screw; Bone Cement; Bone Quality; Bone Substitute; Posterior Surface;
D O I
10.1023/A:1021133819646
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Pedicle screws are widely used to fix posterior spinal implants. However, in some situations, such as at the ends of long constructs in scoliosis correction, the screws may pull out of the pedicles. This limits the use of pedicle screw fixation where bone quality is poor. The aim of this study was to investigate the effect of using either a low-viscosity bone cement (Palacos LV) or a bone augmentation material (Cortoss) on the pullout strength of typical pedicle screws (5 mm USS Schanz screws). Ten lumbar calf vertebrae were implanted with pedicle screws. One screw was inserted as normal, and the contralateral screw was augmented with Palacos LV or Cortoss. A plate was then cemented to the posterior surface of each pedicle and the screws were pulled out using a tensile testing machine. The pullout strength of the non-augmented screws was 1203 +/- 260 N, while the pullout strength of the augmented screws was 1970 +/- 220 N (Palacos LV) and 2021 +/- 342 N (Cortoss). Both Palacos LV and Cortoss significantly increased the pullout strength (p=0.0213 and p=0.0029, respectively). There was no significant difference between the Palacos LV and Cortoss groups (p=0.79). (C) 2002 Kluwer Academic Publishers.
引用
收藏
页码:1143 / 1145
页数:3
相关论文
共 8 条
[1]
Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute [J].
Bai, B ;
Kummer, FJ ;
Spivak, J .
SPINE, 2001, 26 (24) :2679-2683
[2]
Axial and tangential fixation strength of pedicle screws versus hooks in the thoracic spine in relation to bone mineral density [J].
Hackenberg, L ;
Link, T ;
Liljenqvist, U .
SPINE, 2002, 27 (09) :937-942
[3]
A 20-YEAR PERSPECTIVE ON THE MECHANICAL-PROPERTIES OF TRABECULAR BONE [J].
KEAVENY, TM ;
HAYES, WC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :534-542
[4]
Hip screw augmentation with an in situ setting calcium phosphate cement: An in vitro biomechanical analysis [J].
Moore, DC ;
Frankenburg, EP ;
Goulet, JA ;
Goldstein, SA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) :577-583
[5]
Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines [J].
Sarzier, JS ;
Evans, AJ ;
Cahill, DW .
JOURNAL OF NEUROSURGERY, 2002, 96 (03) :309-312
[6]
WEINSTEIN JN, 1992, CLIN ORTHOP RELAT R, P34
[7]
NEUROLOGICAL DETERIORATION AFTER CEMENT INJECTION INTO A VERTEBRAL BODY [J].
WILKES, RA ;
MACKINNON, JG ;
THOMAS, WG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :155-155
[8]
WITTENBERG RH, 1993, CLIN ORTHOP RELAT R, P278