Evaluation of a high-resolution time-of-flight mass spectrometer for the gas chromatographic determination of selected environmental contaminants

被引:18
作者
Dallüge, J
Roose, P
Brinkman, UAT
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
[2] Inst Royal Sci Nat Belgique, Manamgement Unit Math Models N Sea, B-8400 Oostende, Belgium
关键词
high-resolution time-of-flight mass spectrometer; mass spectrometer; pesticides; polynuclear aromatic hydrocarbons; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(02)00233-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A benchtop high-resolution time-of-flight mass spectrometer (TOP MS) was evaluated for the determination of key organic microcontaminants. The major advantage of the TOF MS proved to be, the high mass resolution of, about 0.002 Da (10 ppm). Consequently, the detectability of polar pesticides, polynuclear aromatic hydrocarbons and polychlorinated biphenyls is excellent, and detection limits are in the order of 1-4 pg injected mass. Best mass spectral resolution was obtained for medium-scale peaks. It is a disadvantage that the calibration range is rather limited, viz. to about two orders of magnitude. The high mass spectral resolution was especially useful to improve-the selectivity and sensitivity when analyzing target compounds in complex samples and to prevent false-positive identifications. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 223
页数:11
相关论文
共 13 条
[1]  
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[2]  
Dallüge J, 2002, J SEP SCI, V25, P201, DOI 10.1002/1615-9314(20020301)25:4<201::AID-JSSC201>3.3.CO
[3]  
2-2
[4]   COMPARISON OF GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC METHODS FOR SCREENING OF CHLOROTRIAZINE PESTICIDES IN SOIL [J].
DURAND, G ;
GILLE, P ;
FRAISSE, D ;
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY, 1992, 603 (1-2) :175-184
[5]   GC/MS analysis of toxaphene: A comparative study of different mass spectrometric techniques. [J].
Lau, B ;
Weber, D ;
Andrews, P .
CHEMOSPHERE, 1996, 32 (06) :1021-1041
[6]   Basic aspects of methods for the determination of dioxins and PCBs in foodstuffs and human tissues [J].
Liem, AKD .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (06) :429-439
[7]   A comparison of three mass spectrometric methods for the determination of dioxins/furans [J].
March, RE ;
Splendore, M ;
Reiner, EJ ;
Mercer, RS ;
Plomley, JB ;
Waddell, DS ;
MacPherson, KA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 194 (2-3) :235-246
[8]   Comparison of GC-ECD, GC-MS and GC-AED for the determination of polychlorinated biphenyls in highly contaminated marine sediments [J].
PedersenBjergaard, S ;
Semb, SI ;
Vedde, J ;
Brevik, EM ;
Greibrokk, T .
CHROMATOGRAPHIA, 1996, 43 (1-2) :44-52
[9]   High resolution time-of-flight spectrometry [J].
Short, RT .
PHYSICA SCRIPTA, 1997, T71 :46-49
[10]   Identification of non-target compounds using gas chromatography with simultaneous atomic emission and mass spectrometric detection (GC-AED/MS): analysis of municipal wastewater [J].
van Stee, LLP ;
Leonards, PEG ;
Vreuls, RJJ ;
Brinkman, UAT .
ANALYST, 1999, 124 (11) :1547-1552