Identification of non-target compounds using gas chromatography with simultaneous atomic emission and mass spectrometric detection (GC-AED/MS): analysis of municipal wastewater

被引:41
作者
van Stee, LLP [1 ]
Leonards, PEG [1 ]
Vreuls, RJJ [1 ]
Brinkman, UAT [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1039/a905295j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parallel atomic emission (AED) and mass spectrometric detection (MSD) was used for the gas chromatographic (GC) analysis of non-target compounds in influent and effluent water of a sewage treatment plant. Because of their potential environmental impact, non-target analysis was mainly focused on chlorinated compounds. With solid-phase extraction (SPE, styrene-divinylbenzene copolymer adsorbent) for analyte enrichment from 25 ml of aqueous sample, detection limits were 0.2-0.5 mu g l(-1) for these compounds. After screening for chlorinated compounds with AED, the essentially identical retention times observed with both detectors allowed their precise allocation in the MS total ion chromatogram. In this way, seven non-target chlorinated compounds could be identified. Furthermore, some 20 of the most abundant compounds present in the influent were also identified, and the GC profiles of the influents and effluents were compared. The removal of GC-amenable compounds in the treatment plant was 85-90%. However, several compounds, such as the flame retardants Fyrol PCF and Fyrol CEF, were not efficiently removed, and were detected in the effluent at concentrations of up to 1 mu g l(-1).
引用
收藏
页码:1547 / 1552
页数:6
相关论文
共 15 条
[1]   Method translation and retention time locking in partition GC [J].
Blumberg, LM ;
Klee, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3828-3839
[2]  
DAVID F, 1991, HRC-J HIGH RES CHROM, V14, P554
[3]   The potential of gas chromatography with microwave-induced plasma atomic emission detection (GC-MIP-AED) as a complementary analytical technique in environmental screening analysis of aqueous samples [J].
Frischenschlager, H ;
Mittermayr, C ;
Peck, M ;
Rosenberg, E ;
Grasserbauer, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (03) :213-221
[4]  
GIARROCCO V, 1997, 228393 HEWL PACK
[5]   Data correlation in on-line solid-phase extraction gas chromatography atomic emission mass spectrometric detection of unknown microcontaminants [J].
Hankemeier, T ;
Rozenbrand, J ;
Abhadur, M ;
Vreuls, JJ ;
Brinkman, UAT .
CHROMATOGRAPHIA, 1998, 48 (3-4) :273-283
[6]   CGC/AED and CGC/ECD/NPD comparison for the determination of acaricides in honey after hexane acetone extraction [J].
Jimenez, JJ ;
Bernal, JL ;
Atienza, J .
CHROMATOGRAPHIA, 1996, 42 (3-4) :130-134
[7]  
Mol H. G. J., 1999, LC GC EUR, V12, P108
[8]  
NGUYEN DK, 1994, HRC-J HIGH RES CHROM, V17, P153, DOI 10.1002/jhrc.1240170306
[9]   IDENTIFICATION OF CHLORINATED SULFUR-COMPOUNDS IN PULP-MILL EFFLUENTS BY GC-MS AND GC-AED [J].
PEDERSENBJERGAARD, S ;
ASP, TN ;
VEDDE, J ;
CARLBERG, GE ;
GREIBROKK, T .
CHROMATOGRAPHIA, 1993, 35 (3-4) :193-198
[10]   Environmental screening by capillary gas chromatography combined with mass spectrometry and atomic emission spectroscopy [J].
PedersenBjergaard, S ;
Semb, SI ;
Vedde, J ;
Brevik, EM ;
Greibrokk, T .
CHEMOSPHERE, 1996, 32 (06) :1103-1115