Environmental screening by capillary gas chromatography combined with mass spectrometry and atomic emission spectroscopy

被引:15
作者
PedersenBjergaard, S [1 ]
Semb, SI [1 ]
Vedde, J [1 ]
Brevik, EM [1 ]
Greibrokk, T [1 ]
机构
[1] NORWEGIAN INST WATER RES,N-0411 OSLO,NORWAY
关键词
capillary gas chromatography; mass spectrometry; atomic emission spectroscopy; environmental analysis;
D O I
10.1016/0045-6535(96)00013-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Capillary gas chromatography (GC) combined with mass spectrometry (MS) and atomic emission spectroscopy (AED) was utilized for a comprehensive investigation of organic micropollutants in a marine sediment. Most compounds were found and identified by CC-MS library search. The elemental information from GC-AED was utilized for confirmation purposes, for analyte characterization in cases where identification by CC-MS was impossible, and for screening on heteroatomic components. In addition, GC-AED was effectively used for the quantitative part, where the total amount of GC amenable material, classes of compounds, and individual components were determined.
引用
收藏
页码:1103 / 1115
页数:13
相关论文
共 46 条
[1]  
ALBRO TG, 1993, HRC-J HIGH RES CHROM, V16, P13
[2]   FIRST RESULTS IN TRACE IDENTIFICATION OF ALLELOCHEMICALS AND PHEROMONES BY COMBINING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND DIRECT DEPOSITION GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY [J].
AUGER, J ;
FERARY, S .
JOURNAL OF CHROMATOGRAPHY A, 1994, 683 (01) :87-94
[3]   ANALYSIS OF POLYCHLORINATED-BIPHENYLS (PCB) BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY - COMPOSITION OF TECHNICAL AROCLOR-PCB AND CLOPHEN-PCB MIXTURES [J].
BALLSCHMITER, K ;
ZELL, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (01) :20-31
[4]   SEPARATION AND CHARACTERIZATION OF ISOMERS OF PARA-NONYLPHENOLS BY CAPILLARY GC/GC-MS/GC-FTIR TECHNIQUES [J].
BHATT, BD ;
PRASAD, JV ;
KALPANA, G ;
ALI, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1992, 30 (06) :203-210
[5]   DETERMINATION OF SULFURATED COMPOUNDS IN TAGETES-PATULA CV NANA ESSENTIAL OIL BY GAS-CHROMATOGRAPHY WITH MASS-SPECTROMETRIC, FOURIER-TRANSFORM INFRARED AND ATOMIC EMISSION SPECTROMETRIC DETECTION [J].
BICCHI, C ;
FRATTINI, C ;
PELLEGRINO, G ;
RUBIOLO, P ;
RAVERDINO, V ;
TSOUPRAS, G .
JOURNAL OF CHROMATOGRAPHY, 1992, 609 (1-2) :305-313
[7]  
BUDZINSKI H, 1992, ANALUSIS, V20, P155
[8]   PYROLYSIS-GAS CHROMATOGRAPHY-MASS SPECTROMETRY AND PYROLYSIS - GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED FLAME IONIZATION DETECTION STUDIES OF PARTICLE-SIZE FRACTIONS OF WOODY PEAT [J].
CALVERT, GD ;
ESTERLE, JS ;
DURIG, JR .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1989, 16 (01) :5-25
[9]  
DAVID F, 1991, HRC-J HIGH RES CHROM, V14, P554
[10]   COMPARISON OF THE GC/MS ION TRAPPING TECHNIQUE WITH GC-FTIR FOR THE IDENTIFICATION OF STIMULANTS IN DRUG-TESTING [J].
DEJONG, EG ;
KEIZERS, S ;
MAES, RAA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1990, 14 (02) :127-131