Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples

被引:129
作者
Long, F. [1 ]
He, M. [1 ]
Zhu, A. N. [1 ]
Shi, H. C. [1 ]
机构
[1] Tsinghua Univ, Dept Environm Sci & Engn, Environm Simulate & Pollut Control State Key Join, Beijing 100084, Peoples R China
关键词
Evanescent wave immunosensor; Microcystin-LR; Total internal reflection; Fluorescence; Environmental analysis; SURFACE-PLASMON RESONANCE; PHOSPHATASE INHIBITION ASSAY; SELF-ASSEMBLED MONOLAYER; ALL-FIBER IMMUNOSENSOR; CYANOBACTERIA; CHROMATOGRAPHY; IMMUNOASSAY; CYANOTOXINS; ANTIBODIES; BIOSENSORS;
D O I
10.1016/j.bios.2008.12.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Fast and sensitive detection of microcystin-LR (MC-LR) was conducted with a portable trace organic pollutant analyzer (TOPA) based on the principle of immunoassay and total internal reflection fluorescence. The reusable fiber optic probe surface was produced by covalently immobilizing a MC-LR-ovalbumin (MC-LR-OVA) conjugate onto a self-assembled thiol-silane monolayer of fiber optic probe through a heterobifunctional reagent. It has been established that the MC-LR-OVA immobilized fiber optic probe is highly resistive to non-specific binding of proteins, while bound anti-MC-LR antibody can easily be eluted from the immunosurface with high recoveries (more than 150 assay cycles) in the way of pepsin solution, without any damage to the surface-immobilized MC-LR derivatives. One assay cycle including surface regeneration was less than 20 min. For the standard curve, the limit of detection (LOD) of 0.03 mu g/L and the quantitative detection range of 0.1-10.1 mu g/L was obtained when the concentration of antibody labeled by Cy5.5 was 0.28 mu g/mL. Cross-reactivity against a few compounds structurally similar to MC-LR was little. The developed immunosensor method was applied to the monitoring of MC-LR in various types of water. The recovery of MC-LR added to water samples at different concentrations ranged from 80 to 110% with relative standard deviation (R.S.D.) values less than 5%. The immunoassay performance of the TOPA was validated with respect to conventional high-performance liquid chromatography, and the correlation between methods was in good agreement (r(2) = 0.9978). The TOPA is a portable, easy-to-use, and robust immunoassay system and commercially obtained from the company JQ-environ Co. Ltd. (China). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2346 / 2351
页数:6
相关论文
共 37 条
[1]
USE OF A COLORIMETRIC PROTEIN PHOSPHATASE INHIBITION ASSAY AND ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR THE STUDY OF MICROCYSTINS AND NODULARINS [J].
AN, JS ;
CARMICHAEL, WW .
TOXICON, 1994, 32 (12) :1495-1507
[2]
[Anonymous], 2004, World Health Organization Guidelines for Drinking Water Quality Third Edition, V1
[3]
USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[4]
Bhattacharya R., 1997, Biomedical and Environmental Sciences, V10, P93
[5]
Highly sensitive amperometric immunosensors for microcystin detection in algae [J].
Campas, Monica ;
Marty, Jean-Louis .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :1034-1040
[6]
COMPARATIVE-ASSESSMENT OF THE SPECIFICITY OF THE BRINE SHRIMP AND MICROTOX ASSAYS TO HEPATOTOXIC (MICROCYSTIN-LR-CONTAINING) CYANOBACTERIA [J].
CAMPBELL, DL ;
LAWTON, LA ;
BEATTIE, KA ;
CODD, GA .
ENVIRONMENTAL TOXICOLOGY AND WATER QUALITY, 1994, 9 (01) :71-77
[7]
Human fatalities from cyanobacteria: Chemical and biological evidence for cyanotoxins [J].
Carmichael, WW ;
Azevedo, SMFO ;
An, JS ;
Molica, RJR ;
Jochimsen, EM ;
Lau, S ;
Rinehart, KL ;
Shaw, GR ;
Eaglesham, GK .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2001, 109 (07) :663-668
[8]
Harada K., 1999, Toxic cyanobacteria in water: a guide to their public health consequences, monitoring, and management
[9]
Inhibition of several protein phosphatases by a non-covalently interacting microcystin and a novel cyanobacterial peptide, nostocyclin [J].
Hastie, CJ ;
Borthwick, EB ;
Morrison, LF ;
Codd, GA ;
Cohen, PTW .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2005, 1726 (02) :187-193
[10]
Determination of cyanobacterial hepatotoxins directly in water using a protein phosphatase inhibition assay [J].
Heresztyn, T ;
Nicholson, BC .
WATER RESEARCH, 2001, 35 (13) :3049-3056