Continuous cervical spine kinematics during in vivo dynamic flexion-extension

被引:33
作者
Anderst, William J. [1 ]
Donaldson, William F., III [1 ]
Lee, Joon Y. [1 ]
Kang, James D. [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA 15203 USA
关键词
Percent contribution; Anterior cervical fusion; Adjacent segment disease; FINITE-ELEMENT MODEL; LEVEL INTRADISCAL PRESSURE; INTERVERTEBRAL MOTION; MECHANICAL-PROPERTIES; DISC ARTHROPLASTY; SEGMENTAL MOTION; FUSION; ADJACENT; VALIDATION; RANGE;
D O I
10.1016/j.spinee.2013.08.019
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND CONTEXT: A precise and comprehensive definition of "normal" in vivo cervical kinematics does not exist due to high intersubject variability and the absence of midrange kinematic data. In vitro test protocols and finite element models that are validated using only end range of motion data may not accurately reproduce continuous in vivo motion. PURPOSE: The primary objective of this study was to precisely quantify cervical spine intervertebral kinematics during continuous, functional flexion-extension in asymptomatic subjects. The advantages of assessing continuous intervertebral kinematics were demonstrated by comparing asymptomatic controls with patients with single-level anterior arthrodesis. STUDY DESIGN: Cervical spine kinematics were determined during continuous in vivo flexion-extension in a clinically relevant age group of asymptomatic controls and a group of patients with C5-C6 arthrodesis. PATIENT SAMPLE: The patient sample consisted of 6 patients with single-level (C5-C6) anterior arthrodesis (average age: 48.8 +/- 6.9 years; 1 male, 5 female; 7.6 +/- 1.2 months postsurgery) and 18 asymptomatic control subjects of similar age (average age: 45.6 +/- 5.8 years; 5 male, 13 female). OUTCOME MEASURES: Outcome measures included the physiologic measure of continuous kinematic motion paths at each cervical motion segment (C2-C7) during flexion-extension. METHODS: Participants performed flexion-extension while biplane radiographs were collected at 30 images per second. A previously validated tracking process determined three-dimensional vertebral positions with submillimeter accuracy. Continuous flexion-extension rotation and anterior-posterior translation motion paths were adjusted for disc height and static orientation of each corresponding motion segment. RESULTS: Intersubject variability in flexion-extension angle was decreased 15% to 46% and intersubject variability in anterior-posterior translation was reduced 14% to 33% after adjusting for disc height and static orientation angle. Average intersubject variability in continuous motion paths was 1.9 degrees in flexion-extension and 0.6 mm in translation. Third-order polynomial equations were determined to precisely describe the continuous flexion-extension and anterior-posterior translation motion path at each motion segment (all R-2>0.99). CONCLUSIONS: A significant portion of the intersubject variability in cervical kinematics can be explained by the disc height and the static orientation of each motion segment. Clinically relevant information may be gained by assessing intervertebral kinematics during continuous functional movement rather than at static, end range of motion positions. The fidelity of in vitro cervical spine mechanical testing protocols may be evaluated by comparing in vitro kinematics to the continuous motion paths presented. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1221 / 1227
页数:7
相关论文
共 43 条
[1]
Validation of three-dimensional model-based tibio-femoral tracking during running [J].
Anderst, William ;
Zauel, Roger ;
Bishop, Jennifer ;
Demps, Erinn ;
Tashman, Scott .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) :10-16
[2]
Six-Degrees-of-Freedom Cervical Spine Range of Motion During Dynamic Flexion-Extension After Single-Level Anterior Arthrodesis Comparison with Asymptomatic Control Subjects [J].
Anderst, William J. ;
Lee, Joon Y. ;
Donaldson, William F., III ;
Kang, James D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (06) :497-506
[3]
Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement [J].
Anderst, William J. ;
Baillargeon, Emma ;
Donaldson, William F., III ;
Lee, Joon Y. ;
Kang, James D. .
SPINE, 2011, 36 (06) :E393-E400
[4]
Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics [J].
Bey, Michael J. ;
Zauel, Roger ;
Brock, Stephanie K. ;
Tashman, Scott .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :604-609
[5]
Normal Functional Range of Motion of the Cervical Spine During 15 Activities of Daily Living [J].
Bible, Jesse E. ;
Biswas, Debdut ;
Miller, Christopher P. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (01) :15-21
[6]
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[7]
Anterior cervical fixation: Analysis of load-sharing and stability with use of static and dynamic plates [J].
Brodke, Darrel S. ;
Klimo, Paul, Jr. ;
Bachus, Kent N. ;
Braun, John T. ;
Dailey, Andrew T. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (07) :1566-1573
[8]
Development of a finite element model of the upper cervical spine and a parameter study of ligament characteristics [J].
Brolin, K ;
Halldin, P .
SPINE, 2004, 29 (04) :376-385
[9]
Task-Specific Frequencies of Neck Motion Measured in Healthy Young Adults Over a Five-Day Period [J].
Cobian, Daniel G. ;
Sterling, Andrew C. ;
Anderson, Paul A. ;
Heiderscheit, Bryan C. .
SPINE, 2009, 34 (06) :E202-E207
[10]
Comparison of cervical disk implants and cervical disk fusion treatments in human cadaveric models [J].
Davies, M. A. ;
Bryant, S. C. ;
Larsen, S. P. ;
Murrey, D. B. ;
Nussman, D. S. ;
Laxer, E. B. ;
Darden, B. V., III .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :481-486