Assessment of 18F PET signals for automatic target volume definition in radiotherapy treatment planning

被引:68
作者
Davis, J. Bernard
Reiner, Beatrice
Huser, Marius
Burger, Cyrill
Szekely, Gabor
Ciernik, I. Frank
机构
[1] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Comp Vis Lab, Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Nucl Med, CH-8091 Zurich, Switzerland
关键词
FDG-PET; functional imaging-based radiotherapy planning; PET/CT-derived target volume definition; segmentation of PET signals; threshold definition; automatic 3D delineation of PET images;
D O I
10.1016/j.radonc.2006.07.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Positron emission tomography (PET) alone or in combination with computer tomography (PET/CT) is increasingly used in target volume assessment. A standardized way of converting PET signals into target volumes is not available at present. Materials and methods: Assuming a uniform signal emission from a tumour and surrounding normal tissues, a model-based method was developed to determine a relative threshold level (Th-rel) for gross tumour volume delineation. Two phantoms consisting of cylindrical and spherical sources of diameter ranging from 4.5 to 43 mm in a tank and F-18 activities ranging from 0.001 to 0.15 MBq/ml for tank and sources, respectively, were used for PET/CT imaging. A Th-rel was calculated that best corresponded to the physical diameter of the cylindrical sources. Software (SW) was generated to automatically delineate volumes based on this threshold. The SW was validated for in vitro and in vivo PET signals. Results: The Th-rel best representing the source diameter was 41 +/- 2.5% (95% confidence level) of the background-subtracted signal. The mean deviation for sources of diameter >= 12.5 mm was <= 1.5 mm. The Th-rel was constant for diameters >= 12.5 mm. For source diameters < 12.5 mm, the 41% level over-estimated the real source diameter by a factor depending on the diameter. In an in vitro set-up the SW was capable of segmenting solitary PET volumes to within 1.4 mm (1SD). For non-homogeneous signals in a clinical set-up minimal manual intervention is presently required to separate target from non-target signals. The SW may slightly underestimate target volumes when compared with CT-based volumes, but works well as a first approximation. The volume can be manually adapted to give the ultimate target volume. Conclusions: SW-based automatic delineation of the volume of F-18 activity is feasible and highly reproducible. Volumes can be subsequently modified by the clinician if necessary. This approach will increase the efficiency of the planning process. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 40 条
[1]   High-tech in radiation oncology: Should there be a ceiling? [J].
Bentzen, SM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (02) :320-330
[2]   Defining a radiotherapy target with positron emission tomography [J].
Black, QC ;
Grills, IS ;
Kestin, LL ;
Wong, CYO ;
Wong, JW ;
Martinez, AA ;
Yan, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1272-1282
[3]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[4]   Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT:: The impact of 18FDG-hybrid PET fusion [J].
Caldwell, CB ;
Mah, K ;
Ung, YC ;
Danjoux, CE ;
Balogh, JM ;
Ganguli, SN ;
Ehrlich, LE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :923-931
[5]   18F-FDG positron emission tomography staging and restaging in rectal cancer treated with preoperative chemoradiation [J].
Calvo, FA ;
Domper, M ;
Matute, R ;
Martínez-Lázaro, R ;
Arranz, JA ;
Desco, M ;
Alvarez, E ;
Carreras, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (02) :528-535
[6]   Automated functional image-guided radiation treatment planning for rectal cancer [J].
Ciernik, IF ;
Huser, M ;
Burger, C ;
Davis, JB ;
Szekely, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :893-900
[7]   Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT):: A feasibility study [J].
Ciernik, IF ;
Dizendorf, E ;
Baumert, BG ;
Reiner, B ;
Burger, C ;
Davis, JB ;
Lütolf, UM ;
Steinert, HC ;
Von Schulthess, GK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :853-863
[8]  
Cohade C, 2003, J NUCL MED, V44, P1797
[9]   Positron emission tomography scanning: Current and future applications [J].
Czernin, J ;
Phelps, ME .
ANNUAL REVIEW OF MEDICINE, 2002, 53 :89-112
[10]   Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients:: accuracy, reproducibility and consistency [J].
Daisne, JF ;
Sibomana, M ;
Bol, A ;
Cosnard, G ;
Lonneux, M ;
Grégoire, V .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :237-245