Electrospray ionization and matrix-assisted laser desorption ionization mass spectrometry - Emerging technologies in biomedical sciences

被引:33
作者
Bakhtiar, R
Nelson, RW
机构
[1] Stevens Inst Technol, Dept Chem & Chem Engn, Hoboken, NJ 07030 USA
[2] Intrins Bioprobes Inc, Tempe, AZ 85281 USA
关键词
proteomics; non-covalent complexes; sequencing; high throughput mass spectrometry; combinatorial chemistry; biomolecular interaction analysis;
D O I
10.1016/S0006-2952(99)00317-2
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Tremendous progress in biomedical sciences has been made possible in part by recent advances in bioanalytical methods, in particular biological mass spectrometry. Since the introduction of electrospray ionization mass spectrometry (ESI-MS) in 1984 and matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) in 1988, the field of bioanalytical mass spectrometry has seen rapid growth. In concert with separation techniques such as capillary electrophoresis and high performance liquid chromatography, mass spectrometry allows characterization of a large array of small organic molecules, peptides, proteins, oligonucleotides, and RNA fragments. Thus, substantially more expedient and definitive determination of molecular weight is now possible by mass spectrometric analysis. In this commentary, general descriptions of ESI- and MALDI-MS are presented. Furthermore, several recent developments and applications in addressing difficult biological problems are discussed. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:891 / 905
页数:15
相关论文
共 178 条
  • [1] Abian J, 1999, J MASS SPECTROM, V34, P244, DOI 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO
  • [2] 2-0
  • [3] [Anonymous], 1997, MOL TOXICOLOGY
  • [4] Regulation of PTP1B via glutathionylation of the active site cysteine 215
    Barrett, WC
    DeGnore, JP
    König, S
    Fales, HM
    Keng, YF
    Zhang, ZY
    Yim, MB
    Chock, PB
    [J]. BIOCHEMISTRY, 1999, 38 (20) : 6699 - 6705
  • [5] Bateman R., 1998, ADV MASS SPECTROM, V14, P1
  • [6] Stable acetaldehyde-protein adducts as biomarkers of alcohol exposure
    Birt, JEEC
    Shuker, DEG
    Farmer, PB
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 1998, 11 (02) : 136 - 142
  • [7] Determining affinity-selected ligands and estimating binding affinities by online size exclusion chromatography liquid chromatography-mass spectrometry
    Blom, KF
    Larsen, BS
    McEwen, CN
    [J]. JOURNAL OF COMBINATORIAL CHEMISTRY, 1999, 1 (01): : 82 - 90
  • [8] Regulation of activity of the transcription factor GATA-1 by acetylation
    Boyes, J
    Byfield, P
    Nakatani, Y
    Ogryzko, V
    [J]. NATURE, 1998, 396 (6711) : 594 - 598
  • [9] Atmospheric pressure ionization LC/MS/MS techniques for drug disposition studies
    Brewer, E
    Henion, J
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (04) : 395 - 402
  • [10] PROBE IMMOBILIZED AFFINITY-CHROMATOGRAPHY MASS-SPECTROMETRY
    BROCKMAN, AH
    ORLANDO, R
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (24) : 4581 - 4585