Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers

被引:173
作者
Rosset, Samuel [1 ]
Niklaus, Muhamed [1 ]
Dubois, Philippe [1 ]
Shea, Herbert R. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Microsyst Space Technol Lab, CH-2002 Neuchatel, Switzerland
基金
瑞士国家科学基金会;
关键词
MECHANICAL-PROPERTIES; BULGE-TEST; THIN; FILMS; INTERCONNECTS; DEFORMATION; PERFORMANCE; ACTUATORS; DESIGN;
D O I
10.1002/adfm.200801218
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Here, the use of low-energy metal ion implantation by filtered cathodic vacuum arc to create highly deformable electrodes on polydimethylsiloxane (PDMS) membranes is reported. Implantation leads to the creation of nanometer-size clusters in the first 50 nm below the surface. When the elastomer is stretched, these small clusters can move relative to one another, maintaining electrical conduction at strains of up to 175%. Sheet resistance versus ion dose, resistance versus strain, time stability of the resistance, and the impact of implantation on the elastomer's Young's modulus are investigated for gold, palladium, and titanium implantations. Of the three tested metals, gold has the best performance, combining low and stable surface resistance, very high strain capabilities before loss of conduction, and low impact on the Young's modulus of the PDMS membrane. These electrodes are cyclically strained to 30% for more than 10(5) cycles and remain conductive. In contrast, sputtered or evaporate metals films cease to conduct at strains of order 3%. Additionally, metal ion implantation allows for creating semi-transparent electrodes. The optical transmission through 25-mu m-thick PDMS membranes decreases from 90% to 60% for Pd implantations at doses used to make stretchable electrodes. The implantation technique presented here allows the rapid production of reliable stretchable electrodes for a number of applications, including dielectric elastomer actuators and foldable or rollable electronics.
引用
收藏
页码:470 / 478
页数:9
相关论文
共 27 条
[1]   Biaxial testing of nanoscale films on compliant substrates: Fatigue and fracture [J].
Alaca, BE ;
Selby, JC ;
Saif, MTA ;
Sehitoglu, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) :2963-2970
[2]  
[Anonymous], P SPIE
[3]  
ASCHWANDEN M, 2007, P SPIE, V6524
[4]   Artificial muscles [J].
Ashley, S .
SCIENTIFIC AMERICAN, 2003, 289 (04) :52-59
[5]   Two interferometric methods for the mechanical characterization of thin films by bulging tests. Application to single crystal of silicon [J].
Bonnotte, E ;
Delobelle, P ;
Bornier, L ;
Trolard, B ;
Tribillon, G .
JOURNAL OF MATERIALS RESEARCH, 1997, 12 (09) :2234-2248
[6]   Vacuum arc metal plasma production and the transition of processing mode from metal ion beam to dc metal plasma immersion [J].
Brown, IG .
SURFACE & COATINGS TECHNOLOGY, 2001, 136 (1-3) :16-22
[7]   Electromechanical characterisation of dielectric elastomer planar actuators: comparative evaluation of different electrode materials and different counterloads [J].
Carpi, F ;
Chiarelli, P ;
Mazzoldi, A ;
De Rossi, D .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 107 (01) :85-95
[8]   Folded dielectric elastomer actuators [J].
Carpi, Federico ;
Salaris, Claudio ;
De Rossi, Danilo .
SMART MATERIALS AND STRUCTURES, 2007, 16 (02) :S300-S305
[9]   Design of metal interconnects for stretchable electronic circuits [J].
Gonzalez, Mario ;
Axisa, Fabrice ;
BuIcke, Mathieu Vanden ;
Brosteaux, Dominique ;
Vandevelde, Bart ;
Vanfleteren, Jan .
MICROELECTRONICS RELIABILITY, 2008, 48 (06) :825-832
[10]   A facility for characterizing the dynamic mechanical behavior of thin membranes for microelectromechanical systems [J].
Hall, JD ;
Apperson, NE ;
Crozier, BT ;
Xu, C ;
Richards, RF ;
Bahr, DF ;
Richards, CD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (05) :2067-2072