Microparticle detector for biosensor application

被引:10
作者
Gorschlüter, A
Sundermeier, C
Ross, B
Knoll, M
机构
[1] Univ Munster, Inst Chemo & Biosensor eV, D-48149 Munster, Germany
[2] Univ Munster, Inst Phys Chem, D-48149 Munster, Germany
关键词
microparticle; microelectrode; biosensor; binding force;
D O I
10.1016/S0925-4005(02)00072-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the development of a high-sensitivity electrical biosensor that detects analyte molecules labelled by microparticles. Detection is, achieved by measuring electrochemical current changes occurring when bead-labelled analyte molecules get specifically bound to microelectrodes. We present measurements with transducers that bear microelectrode arrays with a large number of microelectrodes connected in parallel as well as single addressable microelectrodes. These measurements reveal the very sensitive detection of even one single microparticle. By using magnetic microbeads a magnetic force can be applied to the beads to remove them from the electrodes. When this force exceeds the specific binding force of the analyte molecule the bound microparticles are removed and a signal is produced. We assume that the transducer could also be used for the determination of specific binding forces. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:158 / 165
页数:8
相关论文
共 26 条
[1]   Detection of antigen-antibody binding events with the atomic force microscope [J].
Allen, S ;
Chen, XY ;
Davies, J ;
Davies, MC ;
Dawkes, AC ;
Edwards, JC ;
Roberts, CJ ;
Sefton, J ;
Tendler, SJB ;
Williams, PM .
BIOCHEMISTRY, 1997, 36 (24) :7457-7463
[2]   Atomic force microscopy in analytical biotechnology [J].
Allen, S ;
Davies, MC ;
Roberts, CJ ;
Tendler, SJB ;
Williams, PM .
TRENDS IN BIOTECHNOLOGY, 1997, 15 (03) :101-105
[3]  
BANGS LB, 1997, IMMUNOLOGICAL APPL M
[4]   A high-sensitivity micromachined biosensor [J].
Baselt, DR ;
Lee, GU ;
Hansen, KM ;
Chrisey, LA ;
Colton, RJ .
PROCEEDINGS OF THE IEEE, 1997, 85 (04) :672-680
[5]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[6]   Biosensor based on force microscope technology [J].
Baselt, DR ;
Lee, GU ;
Colton, RJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02) :789-793
[7]  
BECHINGER C, 2000, PHYS BLATT, V56, P75
[8]  
Cardoso AH, 1998, COLLOID SURFACE A, V144, P207, DOI 10.1016/S0927-7757(98)00645-1
[9]   The BARC biosensor applied to the detection of biological warfare agents [J].
Edelstein, RL ;
Tamanaha, CR ;
Sheehan, PE ;
Miller, MM ;
Baselt, DR ;
Whitman, LJ ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :805-813
[10]   EFFECT OF ELECTROLYTE TYPE ON THE ELECTROPHORETIC MOBILITY OF POLYSTYRENE LATEX COLLOIDS [J].
ELIMELECH, M ;
OMELIA, CR .
COLLOIDS AND SURFACES, 1990, 44 :165-178