A novel strategy to verification of adulteration in alcoholic beverages based on Schlieren effect measurements and chemometric techniques

被引:43
作者
da Costa, RS
Santos, SRB
Almeida, LF
Nascimento, ECL
Pontes, MJC
Lima, RAC
Simoes, SS
Araújo, MCU
机构
[1] Univ Fed Paraiba, CCEN, Dept Quim, BR-58051970 Joao Pessoa, Paraiba, Brazil
[2] Univ Fed Pernambuco, CCEN, Dept Quim Fundamental, Recife, Brazil
关键词
Schliren; beverages; FIA; adulteration;
D O I
10.1016/j.microc.2004.03.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel strategy to evaluation of adulteration in alcoholic beverages based on the measurement of the Schlieren effect using an automated FIA system with photometric detection is proposed. The assay is based on the Schlieren effect produced when beverage samples are injected in a single-line FIA system that uses water as carrier stream and a light-emitting diode-phototransistor photometer controlled by microcomputer as detector. The flow system presents limited mixing conditions which make possible to create gradients of refractive index (Schlieren effect) in the injected sample zone. These gradients are reproducible, characteristic of each alcoholic beverage and undergo specific modifications when adulterations with water or ethanol are imposed. Schlieren effect data of brandies, cachacas, rums, whiskies and vodkas were treated by SIMCA to elaborate class models applied in the evaluation of alcoholic beverages adulteration. Samples of the original matrix of each sort of beverages were adulterated in laboratory by adding water, methanol and ethanol in levels of 5% and 10% (v/v). These samples were used as test set to validate SIMCA class models. The verification of authenticity using Schlieren effect measurements presented good results making possible to identify 100% of the beverages samples adulterated in laboratory and 93% of the actual adulterated alcoholic beverages with confidence levels of 95%. As principal advantage, the automated system does not use reagents to carry out the analysis. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 15 条
[1]   Application of quality control methods for assessing wine authenticity: Use of multivariate analysis (chemometrics) [J].
Arvanitoyannis, IS ;
Katsota, MN ;
Psarra, EP ;
Soufleros, EH ;
Kallithraka, S .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 1999, 10 (10) :321-336
[2]  
BETTERIDGE D, 1978, ANALYST, V103, P897, DOI 10.1039/an9780300897
[3]  
BLINDER F, 1988, FOOD ADDIT CONT, V3, P343
[4]  
dos Santos SRB, 2002, ANALYST, V127, P324
[5]   A spectroscopic refractometer for temperature-independent refractive index detection [J].
Hanning, A ;
Roeraade, J .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1496-1503
[6]  
Huerta M. Dolores, 1998, Journal of Food Composition and Analysis, V11, P363, DOI 10.1006/jfca.1998.0601
[7]   TURBIDIMETRIC DETERMINATION OF SULFATE IN PLANT DIGESTS AND NATURAL-WATERS BY FLOW-INJECTION ANALYSIS WITH ALTERNATING STREAMS [J].
KRUG, FJ ;
ZAGATTO, EAG ;
REIS, BF ;
BAHIA, O ;
JACINTHO, AO ;
JORGENSEN, SS .
ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) :179-187
[8]  
LOMBARDI RJ, 2002, ESTADO SAO PAULO OCT, P21
[9]  
Nagato L. A. F., 2001, Ciencia e Tecnologia de Alimentos, V21, P39, DOI 10.1590/S0101-20612001000100009
[10]   Application of FT-IR spectroscopy to the characterisation and classification of wines, brandies and other distilled drinks [J].
Palma, M ;
Barroso, CG .
TALANTA, 2002, 58 (02) :265-271