Scanning fluorescent microscopy analysis is applicable for absolute and relative cell frequency determinations

被引:24
作者
Bocsi, J
Varga, VS
Molnár, B
Sipos, F
Tulassay, Z
Tárnok, A
机构
[1] Univ Leipzig, Ctr Heart, Dept Pediat Cardiol, Leipzig, Germany
[2] Semmelweis Univ, Dept Pathol 1, Budapest, Hungary
[3] Hungarian Acad Sci, Clin Gastroenterol Res Unit, Budapest, Hungary
[4] Semmelweis Univ, Dept Med 2, Budapest, Hungary
[5] Univ Hosp, Ctr Heart, Dept Pediat Cardiol, Leipzig, Germany
关键词
imaging virtual cytometry; digital slide; scanning fluorescence; slide-based cytometry; laser scanning cytometry; flow cytometry;
D O I
10.1002/cyto.a.20061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Flow cytometry (FCM) and laser scanning cytometry (LSC) are the routine techniques for fluorescent cell analysis. Recently, we developed a scanning fluorescent microscopy (SFM) technique. This study compares SFM to LSC (two slide-based cytometry, SBC, techniques) and FCM, in experimental and clinical settings. Methods: For the relative cell-frequency determinations, HT29 colorectal cancer cells and Ficoll separated blood mononuclear cells (FSBMCs) were serially diluted (from 1:1 to 1:1,000) and measured by each of the three techniques. For the absolute cell number determinations (only for SBC) FSBMCs were smeared on slides, then HT29 cells were placed on the slide with a micromanipulator (5-50 cells). Tumor cells circulating in the peripheral blood were isolated by magnetic separation from clinical blood samples of colorectal cancer patients. All samples were double-stained by CD45 ECD and CAM5.2 FITC antibodies. For slides, TOTO-3 and Hoechst 33258 DNA dyes were applied as nuclear counter staining. Results: in the relative cell frequency determinations, the correlations between the calculated value and measured values by SFM, LSC, and FCM were r(2) = 0.79, 0.62, and 0.84, respectively (for all P < 0.01). in the absolute cell frequency determinations, SFM and LSC correlated to a high degree (r(2) = 0.97; P < 0.01). Conclusions: SFM proved to be a reliable alternative method, providing results comparable to LSC and FCM. SBC proved to be more suitable for rare-cell detection than FCM. SFM with digital slides may prove an acceptable adaptation of conventional fluorescent microscopes in order to perform rare-cell detection. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 43 条
[21]  
Mehes G, 2000, CANCER, V89, P709, DOI 10.1002/1097-0142(20000801)89:3<709::AID-CNCR31>3.0.CO
[22]  
2-L
[23]  
Model MA, 2001, CYTOMETRY, V44, P309, DOI 10.1002/1097-0320(20010801)44:4<309::AID-CYTO1122>3.0.CO
[24]  
2-3
[25]   Three-dimensional reconstruction and analysis of gastric malignancies by electronic slides of consecutive sections and virtual microscopy [J].
Molnar, B ;
Papik, K ;
Tagscherer, A ;
Csendes, G ;
Varga, SV ;
Tulassay, Z ;
Schaefer, R ;
Mahoney, W .
THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING VI, PROCEEDINGS OF, 1999, 3605 :190-199
[26]  
Molnar B, 2001, CLIN CANCER RES, V7, P4080
[27]  
Musco ML, 1998, CYTOMETRY, V33, P290, DOI 10.1002/(SICI)1097-0320(19981101)33:3<290::AID-CYTO2>3.0.CO
[28]  
2-L
[29]  
Netten H, 1997, CYTOMETRY, V28, P1
[30]  
Paddy MR, 1998, METHOD CELL BIOL, V53, P49