Immunoassay with a microtiter plate incorporated multichannel electrochemical detection system

被引:45
作者
Tang, TC
Deng, AP
Huang, HJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
[2] Chia Nan Univ Pharm & Sci, Dept Pharm, Tainan 71712, Taiwan
关键词
D O I
10.1021/ac0112925
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To extend the application of a multichannel electrochemical detector (MED) for immunoassay, a MED system consisting of 8 sets of Pt electrodes in an arrangement fitted with the dimensions of a row of microtiter wells in a microtiter plate and a microcomputer-assisted 16-channel potentiostat was constructed. With this developed MED system, electroactive enzymatic products produced in eight microtiter wells can be analyzed simultaneously with a developed amperometric procedure. To demonstrate the applicability of the MED system for immunoassay, an immunosystem containing rabbit-IgG and alkaline phosphatase-conjugated goat anti rabbit-IgG was studied. From the dynamic range of 10-1000 ng/mL (0.064-6.4 pM) and the detection limit of 1.0 ng/mL (6.4 pM) obtained, the developed MED shows a tremendous improvement in sensitivity, detection limit, and efficiency compared with that obtained from conventional electrochemical immunoassay.
引用
收藏
页码:2617 / 2621
页数:5
相关论文
共 36 条
[1]   AN ENZYME IMMUNOSENSOR FOR THE ELECTROCHEMICAL DETERMINATION OF THE TUMOR-ANTIGEN ALPHA-FETOPROTEIN [J].
AIZAWA, M ;
MORIOKA, A ;
SUZUKI, S .
ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) :61-67
[2]  
Alexander B., 2000, ANAL CHEM, V72, P916
[3]   Employment of a phenoxy-substituted acridinium ester as a long-lived chemiluminescent indicator of glucose oxidase activity and its application in an alkaline phosphatase amplification cascade immunoassay [J].
Brown, RC ;
Weeks, I ;
Fisher, M ;
Harbron, S ;
Taylorson, CJ ;
Woodhead, JS .
ANALYTICAL BIOCHEMISTRY, 1998, 259 (01) :142-151
[4]   Analysis of overlapped chromatographic peaks by multi-channel electrochemical detection [J].
Cao, GM ;
Hoshino, T .
JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) :151-156
[5]  
Carlo M.D., 1996, ANAL CHIM ACTA, V336, P167
[6]   Application of a 32-microband electrode array detection system for liquid chromatography analysis [J].
Chao, MH ;
Huang, HJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :463-470
[7]   SYNTHESIS OF MONO-NUCLEOTIDE AND DINUCLEOTIDE PHOTOAFFINITY PROBES OF RIBONUCLEIC-ACID POLYMERASE [J].
DERIEMER, LH ;
MEARES, CF .
BIOCHEMISTRY, 1981, 20 (06) :1606-1612
[8]  
EDWARDS R, 1997, PRINCIPLES PRACTICE, P325
[9]   Competitive enzyme immunosensor developed on a renewable carbon paste electrode support [J].
Fernández-Sánchez, C ;
Costa-García, A .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :119-127
[10]   Applications of ELISA, Western blotting and immunoaffinity concentration for survey of ginsenosides in crude drugs of Panax species and traditional Chinese herbal medicines [J].
Fukuda, N ;
Tanaka, H ;
Shoyama, Y .
ANALYST, 2000, 125 (08) :1425-1429