Pulsed magnetization transfer contrast in gradient echo imaging: A two-pool analytic description of signal response

被引:86
作者
Pike, GB
机构
[1] McConnell Brain Imaging Center, Montreal Neurological Institute, McGill University, Montreal, Que.
[2] Montreal Neurological Institute, Montreal, Que. H3A 2B4
关键词
magnetic resonance imaging; cross relaxation; magnetization transfer; tissue relaxation;
D O I
10.1002/mrm.1910360117
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetization transfer (MT) imaging with a rapid gradient-echo sequence and pulsed saturation provides an efficient means of acquiring high resolution three-dimensional data in vivo. This paper presents a derivation of the theoretical steady-state signal equation for this sequence based on the two-site coupled Bloch equations. Numerical simulations are used to validate the derived expression and experiments are performed on an agar gel model and normal brain. Experimental agar data indicate that direct saturation of the liquid component can be a major source of signal attenuation whereas MT normally dominates in brain tissue. The signal equation presented here establishes the necessary theory for sequence design and optimization and provides insight into model parameters and experimental results.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 38 条
[1]   TRANSIENT DECAY OF LONGITUDINAL MAGNETIZATION IN HETEROGENEOUS SPIN SYSTEMS UNDER SELECTIVE SATURATION .3. SOLUTION BY PROJECTION OPERATORS [J].
ADLER, RS ;
YEUNG, HN .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 104 (03) :321-330
[2]  
BALABAN R S, 1992, Magnetic Resonance Quarterly, V8, P116
[3]   MAGNETIZATION TRANSFER CONTRAST IN MR IMAGING OF THE HEART [J].
BALABAN, RS ;
CHESNICK, S ;
HEDGES, K ;
SAMAHA, F ;
HEINEMAN, FW .
RADIOLOGY, 1991, 180 (03) :671-675
[4]   CONTRAST IN RAPID MR IMAGING - T1-WEIGHTED AND T2-WEIGHTED IMAGING [J].
BUXTON, RB ;
EDELMAN, RR ;
ROSEN, BR ;
WISMER, GL ;
BRADY, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :7-16
[5]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[6]   IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST [J].
EDELMAN, RR ;
AHN, SS ;
CHIEN, D ;
WEI, L ;
GOLDMANN, A ;
MANTELLO, M ;
KRAMER, J ;
KLEEFIELD, J .
RADIOLOGY, 1992, 184 (02) :395-399
[7]  
EDZES HT, 1978, J MAGN RESON, V31, P207, DOI 10.1016/0022-2364(78)90185-3
[8]   CRANIAL TISSUES - APPEARANCE AT GADOLINIUM-ENHANCED AND NONENHANCED MR-IMAGING WITH MAGNETIZATION-TRANSFER CONTRAST [J].
ELSTER, AD ;
KING, JC ;
MATHEWS, VP ;
HAMILTON, CA .
RADIOLOGY, 1994, 190 (02) :541-546
[9]   QUANTITATIVE H-1 MAGNETIZATION TRANSFER IMAGING INVIVO [J].
ENG, J ;
CECKLER, TL ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :304-314
[10]   APPLICATION OF FOURIER TRANSFORM SPECTROSCOPY TO MAGNETIC RESONANCE [J].
ERNST, RR ;
ANDERSON, WA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (01) :93-+