Lower extremity residual limb slippage within the prosthesis

被引:33
作者
Commean, PK [1 ]
Smith, KE [1 ]
Vannier, MW [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1997年 / 78卷 / 05期
关键词
D O I
10.1016/S0003-9993(97)90160-X
中图分类号
R49 [康复医学];
学科分类号
100215 [康复医学与理疗学];
摘要
Objective: The ability to measure skin surface slippage relative to the internal wall of a lower extremity prosthesis under various loading conditions is important for evaluation of socket fit and function, and creation of finite element models, Skin surface three-dimensional (3D) shape measurements with tracking of fiducial displacements in situ under axial loading of the prosthesis have not previously been reported. Analysis of slippage within the prosthesis has been performed using a new experimental measurement method based on spiral x-ray computed tomography (SXCT) imaging. Design: Small lead markers were placed on the residuum of an adult with a below-knee amputation, and SXCT scans were obtained with the prosthesis in situ under two static axial loading conditions (44.5N and 178N). The 3D scan data were used to assess slippage with three methods: gross displacement of the tibia and distal end of the residuum; relative displacement of markers, and distance measurements between markers. Results: The markers affixed to the below-knee skin surface within the prosthesis were measured. The skin slipped from 2 to 6mm relative to the internal prosthesis wall when an additional load of 133.5N was applied in the axial direction to the distal end of the prosthesis. The tibial remnant moved 10.0mm distally relative to the prosthesis internal wall. Conclusion: This method provides a feasible means for measuring residuum skin slippage relative to the prosthesis and skin deformation relative to tibia within an in situ prosthesis under load. (C) 1997 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation.
引用
收藏
页码:476 / 485
页数:10
相关论文
共 36 条
[1]
[Anonymous], 3 DIMENSIONAL BIOMED
[2]
BISHPLINGHOFF RL, 1990, STATICS DEFORMABLE S
[3]
Precision of surface measurements for below-knee residua [J].
Commean, PK ;
Smith, KE ;
Cheverud, JM ;
Vannier, MW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (05) :477-486
[4]
COMMEAN PK, IN PRESS J BIOMECH
[5]
COMMEAN PK, 1996, IMAGE PROCESSING P S, P2710
[6]
COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION [J].
CRAWFORD, CR ;
KING, KF .
MEDICAL PHYSICS, 1990, 17 (06) :967-982
[7]
AGE-RELATED-CHANGES IN THE MECHANICAL-PROPERTIES OF HUMAN-SKIN [J].
DALY, CH ;
ODLAND, GF .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1979, 73 (01) :84-87
[8]
HUMAN SKIN AS AN ELASTIC MEMBRANE [J].
DANIELSON, DA .
JOURNAL OF BIOMECHANICS, 1973, 6 (05) :539-+
[9]
FAULKNER V, 1988, ORTHOTICS PROSTHET, V41, P57
[10]
COMPUTER DESIGNED PROSTHETIC SOCKET FROM ANALYSIS OF COMPUTED-TOMOGRAPHY DATA [J].
FAULKNER, VW ;
WALSH, NE .