摘要
A direct spectrophotometric flow injection method for the simultaneous determination of nitrite and nitrate has been developed. The method is based on the oxidation of a phosphomolybdenum blue complex by the addition of nitrite and the decrease in absorbance of the blue complex is monitored at 820 nm. The injected sample is split into two segments. One of the streams was directly reacted with the above reagent and detected as nitrite, The other stream was passed through a copperised cadmium reductor column where reduction of nitrate to nitrite occurs, and the sample was then mixed with the reagent and passed through the cell of the spectrophotometer to be detected as nitrite plus nitrate. The conditions for the flow injection manifold parameters were optimised by experimental design and the concentration of nitrite and nitrate was determined in the linear range from 0.05 to 1.15 mug ml(-1) nitrite and 0.06 to 1.6 mug ml(-1) nitrate with a detection limit of 0.01 mug ml(-1) for nitrite and 0.025 mug ml(-1) for nitrate. The method is suitable for the simultaneous determination of nitrite and nitrate in fish and water samples with a sampling rate of 25 2 sample per hour. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:511 / 518
页数:8
相关论文
共 26 条
[1]   Determination of traces of nitrite and nitrate in water by solid phase spectrophotometry [J].
Abbas, MN ;
Mostafa, GA .
ANALYTICA CHIMICA ACTA, 2000, 410 (1-2) :185-192
[2]  
*AFNOR, 1999, QUAL EAU, V3, P127
[3]  
*AFNOR, 1999, QUAL EAU, V3, P209
[4]   Simultaneous spectrophotometric determination of nitrite nitrate by flow-injection analysis [J].
Ahmed, MJ ;
Stalikas, CD ;
TzouwaraKarayanni, SM ;
Karayannis, MI .
TALANTA, 1996, 43 (07) :1009-1018
[6]  
AOAC, 1995, OFF METH AN, P8
[7]   Simultaneous spectrophotometric determination of nitrite and nitrate in water samples by flow-injection analysis [J].
Chen, H ;
Fang, YJ ;
An, TC ;
Zhu, K ;
Lu, JR .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (02) :89-98
[8]  
CORNBLATH M, 1984, J PEDIATR, V32, P421
[9]   DETERMINATION OF NITRATE AND NITRITE IN BLOOD AND URINE BY CHEMI-LUMINESCENCE [J].
COX, RD ;
FRANK, CW .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1982, 6 (03) :148-152
[10]   Electrochemical detection of nitrate and nitrite at a copper modified electrode [J].
Davis, J ;
Moorcroft, MJ ;
Wilkins, SJ ;
Compton, RG ;
Cardosi, MF .
ANALYST, 2000, 125 (04) :737-741