Mesh augmentation during pelvic-floor reconstructive surgery: risks and benefits

被引:88
作者
Baessler, Kaven
Maher, Christopher F.
机构
[1] Charite Univ Hosp Berlin, Dept Gynaecol, D-12200 Berlin, Germany
[2] Royal Hosp Women, Brisbane, Qld, Australia
[3] Mater Hosp, Brisbane, Qld, Australia
关键词
erosion; nonabsorbable implants; pelvic-floor surgery; pelvic-organ prolapse; stress urinary incontinence; synthetic mesh;
D O I
10.1097/01.gco.0000242961.48114.b0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose of review Synthetic meshes are increasingly used in the surgical management of stress urinary incontinence and pelvic-organ prolapse in an attempt to improve success rates and increase the longevity of repairs. This review describes and analyses complications following pelvic-floor procedures employing synthetic meshes. Recent findings Type I monofilament polypropylene mesh with a large pore size is currently the mesh of choice. Chronic inflammation is a typical host response, whereas acute inflammation and predominant CD20+ lymphocyte infiltration represent an adverse host reaction and may result in defective healing. Mesh properties influence the performance and complication rate. Mesh-related complications after midurethral slings and mesh sacrocolpopexies with monofilament polypropylene are rare, An up to 26% mesh erosion rate and up to 38% dyspareunia rate with vaginally i introduced mesh for pelvic-organ prolapse repair has been reported. Concurrent hysterectomy seems to increase mesh erosion rates. Summary Surgeons should be aware of the potential complications of synthetic meshes. Until data on the safety and efficacy of synthetic mesh in vaginal reconstructive surgery emerge, its i routine use outside of clinical trials cannot be recommended.
引用
收藏
页码:560 / 566
页数:7
相关论文
共 51 条
[21]  
Falconer C, 1996, Int Urogynecol J Pelvic Floor Dysfunct, V7, P133, DOI 10.1007/BF01894201
[22]  
Farnsworth BN, 2002, INT UROGYNECOL J PEL, V13, P4
[23]   Complications of transvaginal silicone-coated polyester synthetic mesh sling [J].
Govier, FE ;
Kobashi, KC ;
Kuznetsov, DD ;
Comiter, C ;
Jones, P ;
Dakil, SE ;
James, R .
UROLOGY, 2005, 66 (04) :741-745
[24]   High complication rate identified in sacrocolpopexy patients attributed to silicone mesh [J].
Govier, FE ;
Kobashi, KC ;
Kozlowski, PM ;
Kuznetsov, DD ;
Begley, SJ ;
McGonigle, KF ;
Muntz, HG .
UROLOGY, 2005, 65 (06) :1099-1103
[25]   Long term review of laparoscopic sacrocolpopexy [J].
Higgs, PJ ;
Chua, HL ;
Smith, ARB .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (08) :1134-1138
[26]   Treatment of stress incontinence with the SPARC sling: Intraoperative and early complications of 445 patients [J].
Hodroff, MA ;
Sutherland, SE ;
Kesha, JB ;
Siegel, SW .
UROLOGY, 2005, 66 (04) :760-762
[27]   Posterior intravaginal slingplasty for vaginal prolapse [J].
Jordaan, D. J. ;
Prollius, A. ;
Cronje, H. S. ;
Nel, M. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2006, 17 (04) :326-329
[29]   Complications and untoward effects of the tension-free vaginal tape procedure [J].
Karram, MM ;
Segal, JL ;
Vassallo, BJ ;
Kleeman, SD .
OBSTETRICS AND GYNECOLOGY, 2003, 101 (05) :929-932
[30]   PVDF as a new polymer for the construction of surgical meshes [J].
Klinge, U ;
Klosterhalfen, B ;
Öttinger, AP ;
Junge, K ;
Schumpelick, V .
BIOMATERIALS, 2002, 23 (16) :3487-3493