External audit of photon beams by mailed film dosimetry: Feasibility study

被引:16
作者
Novotny, J
Gomola, I
Izewska, J
Huyskens, D
Dutreix, A
机构
[1] Radiotherapy Department, University Hospital Gasthuisberg, 3000 Leuven
关键词
D O I
10.1088/0031-9155/42/7/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A feasibility study for mailed film dosimetry has been performed. The global reproducibility of the method is better than 2%. It is shown that the normalized sensitometric curve does not depend on photon beam quality in the range from Co-60 gamma-rays to 18 MV x-rays, although the dose per optical density decreases when the energy increases. The fading of the latent image before film processing is only 3% per month and the normalized sensitometric curve is not modified after a period of 51 days between irradiation and processing. Sets of films were mailed to three different institutes for irradiation and returned for processing and evaluation after more than two months in order to verify that mailing of irradiated and unprocessed films does not produce unwanted artefacts. Finally the feasibility of external audits with mailed him dosimetry is illustrated by comparison of beam profiles measured with films and ionization chambers in a polystyrene phantom.
引用
收藏
页码:1277 / 1288
页数:12
相关论文
共 25 条
[1]  
ATTIX FH, 1986, INTRO RADIOLOGICAL P, P411
[2]   Dosimetry of high energy photon and electron beams with CEA films [J].
Cheng, CW ;
Das, IJ .
MEDICAL PHYSICS, 1996, 23 (07) :1225-1232
[3]  
Croft M J, 1987, Radiol Technol, V58, P333
[4]   PRELIMINARY-RESULTS OF A QUALITY ASSURANCE NETWORK FOR RADIOTHERAPY CENTERS IN EUROPE [J].
DUTREIX, A ;
VANDERSCHUEREN, E ;
DERREUMAUX, S ;
CHAVAUDRA, J .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :97-101
[5]   QUALITY-CONTROL OF RADIOTHERAPY CENTERS IN EUROPE - BEAM CALIBRATION [J].
DUTREIX, A ;
DERREUMAUX, S ;
CHAVAUDRA, J ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1994, 32 (03) :256-264
[6]  
Dutreix J, 1969, Ann N Y Acad Sci, V161, P33
[7]   MAILED TL DOSIMETRY PROGRAM FOR MACHINE OUTPUT CHECK AND CLINICAL-APPLICATION IN THE EORTC RADIOTHERAPY GROUP [J].
HANSSON, U ;
JOHANSSON, KA ;
HORIOT, JC ;
BERNIER, J .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :85-90
[8]  
HAUS AG, 1976, J APPL PHOTOGR ENG, V2, P11
[9]   PHOTOGRAPHIC FILM FOR DETERMINATION OF ISODOSE CURVES FROM BETATRON ELECTRON RADIATION [J].
HETTINGER, G ;
SVENSSON, H .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1967, 6 (01) :74-+
[10]   QUALITY ASSURANCE NETWORK IN CENTRAL-EUROPE - EXTERNAL AUDIT ON OUTPUT CALIBRATION FOR PHOTON BEAMS [J].
IZEWSKA, J ;
NOVOTNY, J ;
GWIAZDOWSKA, B ;
KINDLOVA, A ;
KONTRA, G ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
ACTA ONCOLOGICA, 1995, 34 (06) :829-838