Immunoassay for folic acid detection in vitamin-fortified milk based on electrochemical magneto sensors

被引:78
作者
Lermo, A. [1 ]
Fabiano, S. [3 ]
Hernandez, S. [3 ]
Galve, R. [2 ]
Marco, M. -P. [2 ]
Alegret, S. [1 ]
Pividori, M. I. [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Quim, Grup Sensors & Biosensors, Bellaterra 08193, Catalonia, Spain
[2] CSIC, IQAC, AMRg, ES-08034 Barcelona, Catalonia, Spain
[3] Univ Nacl Litoral, Fac Bioquim & Ciencias Biol, Lab Sensors & Biosensors, RA-3000 Santa Fe, Argentina
关键词
Folic acid; Electrochemical immunosensor; Indirect competitive immunoassay; Magnetic beads; Fortified milk; FOOD; ELISA; AMPLIFICATION; SENSITIVITY; BIOTIN; FOLATE; PCR;
D O I
10.1016/j.bios.2008.10.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An immunoassay-based strategy for folic acid in vitamin-fortified milk with electrochemical detection using magneto sensors is described for the first time. Among direct and indirect competitive formats, best performance was achieved with an indirect competitive immunoassay. The immunological reaction for folic acid (FA) detection was performed, for the first time on the magnetic bead as solid support by the covalent immobilization of a protein conjugate BSA-FA on tosyl-activated magnetic bead. Further competition for the specific antibody between FA in the food sample and FA immobilized on the magnetic bead was achieved, followed by the reaction with a secondary antibody conjugated with HRP (AntiIgG-HRP). Then, the modified magnetic beads were easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC) which was also used as the transducer for the electrochemical detection. The performance of the immunoassay-based strategy with electrochemical detection using magneto sensors was successfully evaluated using spiked-milk samples and compared with a novel magneto-ELISA based on optical detection. The detection limit was found to be of the order of mu g l(-1) (13.1 nmol l(-1), 5.8 mu g l(-1)) for skimmed milk. Commercial vitamin-fortified milk samples were also evaluated obtaining good accuracy in the results. This novel strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological and food samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2057 / 2063
页数:7
相关论文
共 28 条
[1]  
Alegret S, 2003, COMP ANAL C, V39, P1, DOI 10.1016/S0166-526X(03)80106-X
[2]  
Bates C J, 2003, ENCY FOOD SCI NUTR, P2559
[3]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[4]  
Caselunghe MB, 2000, FOOD CHEM, V70, P523, DOI 10.1016/S0308-8146(00)00115-1
[5]   A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads and carbon-based screen-printed electrodes (SPCEs) for the detection of polychlorinated biphenyls (PCBs) [J].
Centi, S ;
Laschi, S ;
Fránek, M ;
Mascini, M .
ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) :205-212
[6]  
Chu F. S., 2003, ENCY FOOD SCI NUTR, P3248
[7]   ANTIBODY TO FOLIC-ACID - INCREASED SPECIFICITY AND SENSITIVITY IN ELISA BY USING EPSILON-AMINOCAPROIC ACID MODIFIED BSA AS THE CARRIER PROTEIN [J].
DASSARMA, J ;
DUTTAGUPTA, C ;
ALI, E ;
DHAR, TK .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 184 (01) :1-6
[8]   Genomagnetic assay based on label-free electrochemical detection using magneto-composite electrodes [J].
Erdem, A ;
Pividori, MI ;
Lermo, A ;
Bonanni, A ;
del Valle, M ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) :591-598
[9]  
*FDA, 1996, FOL AC FORT
[10]   Quantification of water-soluble vitamins in milk-based infant formulae using biosensor-based assays [J].
Gao, Yanling ;
Guo, Fei ;
Gokavi, Sumangala ;
Chow, Andrew ;
Sheng, Qinghai ;
Guo, Mingruo .
FOOD CHEMISTRY, 2008, 110 (03) :769-776