Intraobserver and interobserver reliability of automated antral follicle counts made using three-dimensional ultrasound and SonoAVC

被引:67
作者
Deb, S. [1 ]
Jayaprakasan, K. [1 ]
Campbell, B. K. [1 ]
Clewes, J. S. [1 ]
Johnson, I. R. [1 ]
Raine-Fenning, N. J. [1 ]
机构
[1] Univ Nottingham, Sch Human Dev, Nottingham Univ Hosp NHS Trust, Queens Med Ctr,NURTURE, Nottingham NG7 2RD, England
关键词
antral follicle count; automated; interobserver; intraobserver; reliability; SonoAVC; three-dimensional ultrasound; OVARIAN RESERVE; WORK FLOW; AGREEMENT; ULTRASONOGRAPHY; REPRODUCIBILITY; POPULATION; ENDOCRINE; FERTILITY; HORMONE; VOLUME;
D O I
10.1002/uog.6310
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To assess the reliability of automated measurements of the total antral follicle count (AFC) made using Sono-Automatic Volume Count (SonoAVC), and to compare these to two-dimensional (2D) and manual three-dimensional (3D) techniques. Methods Fifty-five subjects aged under 40 years who had 3D transvaginal ultrasound examination in the early follicular phase of their menstrual cycle were prospectively recruited. 3D datasets were acquired and subsequently analyzed. The total AFC (2-10 mm antral follicles) was calculated by two observers using three independent methods. 2D real-time equivalent (2D-RTE), 3D manual multiplanar view (3D-MPV), and SonoAVC. For measurements made using SonoAVC, the initial automated count (sAVC-AA) was recorded and postprocessing (sAVC-PP) then applied to identify follicles that bad been missed or incorrectly included. Intraclass correlation and limits of agreement were used to evaluate the methods. Results The intra- and interobserver reliability of measurements of total AFC was best with SonoAVC with postprocessing followed by 3D-MPV and 2D-RTE. The initial count calculated by sAVC-AA missed follicles and this was reflected in the significantly lower mean total AFC (6.51 +/- 4.79) than that made after postprocessing techniques (sAVC-PP, 18.42 +/- 10.53, P < 0.001; 3D-MPV, 19.38 +/- 10.85, P < 0.001; and 2D-RTE, 19.26 +/- 10.55, P < 0.001). The mean total AFC became more comparable with postprocessing (sAVC-PP) but still remained significantly lower than counts made with 2D-RTE and 3D-MPV (P < 0.05). Conclusion SonoAVC with postprocessing is a reliable method for measuring total AFC. It takes longer to perform, because of the need for postprocessing, and obtains values that are lower than those obtained by the 2D and 3D-MPV techniques. However, the AFC obtained by sAVC-PP is likely to be lower because this method measures and color codes each follicle Preventing recounting. Copyright (C) 2009 ISUOG, Published by John Wiley & Sons, Ltd.
引用
收藏
页码:477 / 483
页数:7
相关论文
共 20 条
  • [1] Altman DG., 1996, PRACTICAL STAT MED R, V7th
  • [2] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [3] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] The number of small antral follicles (2-6 mm) determines the outcome of endocrine ovarian reserve tests in a subfertile population
    Haadsma, M. L.
    Bukman, A.
    Groen, H.
    Roeloffzen, E. M. A.
    Groenewoud, E. R.
    Heineman, M. J.
    Hoek, A.
    [J]. HUMAN REPRODUCTION, 2007, 22 (07) : 1925 - 1931
  • [6] Three-dimensional ultrasound improves the interobserver reliability of antral follicle counts and facilitates increased clinical work flow
    Jayaprakasan, K.
    Campbell, B. K.
    Clewes, J. S.
    Johnson, I. R.
    Raine-Fenning, N. J.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) : 439 - 444
  • [7] The interobserver reliability of off-line antral follicle counts made from stored three-dimensional ultrasound data: a comparative study of different measurement techniques
    Jayaprakasan, K.
    Walker, K. F.
    Clewes, J. S.
    Johnson, I. R.
    Raine-Fenning, N. J.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (03) : 335 - 341
  • [8] Khan KS, 2001, BRIT J OBSTET GYNAEC, V108, P562
  • [9] Forming inferences about some intraclass correlation coefficients
    McGraw, KO
    Wong, SP
    [J]. PSYCHOLOGICAL METHODS, 1996, 1 (01) : 30 - 46
  • [10] Evaluation of the utility of multiple endocrine and ultrasound measures of ovarian reserve in the prediction of cycle cancellation in a high-risk IVF population
    McIlveen, M.
    Skull, J. D.