Effects of sample hardness on human chewing force: a model study using silicone rubber

被引:109
作者
Kohyama, K
Hatakeyama, E
Sasaki, T
Dan, H
Azuma, T
Karita, K
机构
[1] Natl Food Res Inst, Tsukuba, Ibaraki 3058642, Japan
[2] Tohoku Fukushi Univ, Kansei Fukushi Res Ctr, Aoba Ku, Sendai, Miyagi 9818522, Japan
[3] Nitta Corp, RETS Div, Chuo Ku, Tokyo 1040061, Japan
[4] Tohoku Univ, Grad Sch Dent, Dept Oral Diag, Aoba Ku, Sendai, Miyagi 9808575, Japan
关键词
chewing force; sample hardness; silicone rubber; multiple-point sheet sensor (MSS);
D O I
10.1016/j.archoralbio.2004.04.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aims to clarify the effects of sample hardness on chewing force of humans. Silicone rubber was chosen as a food model., and three silicone rubber samples of varying hardness were chewed between the upper and lower incisors or molars in a natural way. Chewing force, contact area between a specimen and teeth, and pressure applied into the specimen were dynamically measured with a multiple-point sheet sensor. The multiple-point measurement revealed that a harder sample evoked higher peak force, longer duration, higher impulse, and higher active pressure values, whereas the chewing cycle and time to peak were not affected by sample hardness. The contact area between the sample and teeth decreased for the harder sample during incisor chewing. The peak force and force-related parameters, contact area, time to peak and bite force duration showed higher values for molar bites than for incisor bites, while the chewing cycle was similar in both cases. The measurement with the sheet sensor system clearly indicated that sample hardness modified chewing force of humans. We hypothesise that the effect of sample hardness is mainly mediated by mechanoreceptors in the periodontal ligament. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:805 / 816
页数:12
相关论文
共 38 条
[21]   Direct measurement of biting pressures for crackers using a multiple-point sheet sensor [J].
Kohyama, K ;
Nishi, M .
JOURNAL OF TEXTURE STUDIES, 1997, 28 (06) :605-617
[22]   Effect of sample thickness on bite force studied with a multiple-point sheet sensor [J].
Kohyama, K ;
Hatakeyama, E ;
Sasaki, T ;
Azuma, T ;
Karita, K .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (04) :327-334
[23]  
Kohyama K., 2001, Food Science and Technology Research, V7, P17, DOI 10.3136/fstr.7.17
[24]   Pressure distribution measurement in biting surimi gels with molars using a multiple-point sheet sensor [J].
Kohyama, K ;
Sakai, T ;
Azuma, T ;
Mizuguchi, T ;
Kimura, I .
BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2001, 65 (12) :2597-2603
[25]   Dynamics of the human masticatory system [J].
Koolstra, JH .
CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 2002, 13 (04) :366-376
[26]  
LAVELLE CLB, 1998, APPL ORAL PHYSL, P12
[27]   EVIDENCE THAT PERIODONTAL PRESSORECEPTORS PROVIDE POSITIVE FEEDBACK TO JAW CLOSING MUSCLES DURING MASTICATION [J].
LAVIGNE, G ;
KIM, JS ;
VALIQUETTE, C ;
LUND, JP .
JOURNAL OF NEUROPHYSIOLOGY, 1987, 58 (02) :342-358
[28]   BITE FORCE DISPLAYED DURING ASSESSMENT OF HARDNESS IN VARIOUS TEXTURE CONTEXTS [J].
MIOCHE, L ;
PEYRON, MA .
ARCHIVES OF ORAL BIOLOGY, 1995, 40 (05) :415-423
[29]  
Nakazawa F, 1999, HYDROCOLLOIDS, PT 2, P473
[30]   A THIN BITE-FORCE TRANSDUCER WITH 3-DIMENSIONAL CAPABILITIES REVEALS A CONSISTENT CHANGE IN BITE-FORCE DIRECTION DURING HUMAN JAW-MUSCLE ENDURANCE TESTS [J].
OSBORN, JW ;
MAO, J .
ARCHIVES OF ORAL BIOLOGY, 1993, 38 (02) :139-144