Development and characterization of an integrated silicon micro flow cytometer

被引:34
作者
Bernini, R.
De Nuccio, E.
Brescia, F.
Minardo, A.
Zeni, L.
Sarro, P. M.
Palumbo, R.
Scarfi, M. R.
机构
[1] CNR, IREA, I-80124 Naples, Italy
[2] Univ Naples Federico II, DII, I-81031 Aversa, Italy
[3] Delft Univ Technol, ECTM, DIMES, NL-2600 Delft, Netherlands
[4] CNR, IBB, I-80134 Naples, Italy
关键词
microfluidics; microfabrication; optical sensors; biochips; high-throughput screening;
D O I
10.1007/s00216-006-0623-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes an innovative integrated micro flow cytometer that presents a new arrangement for the excitation/detection system. The sample liquid, containing the fluorescent marked particles/cells under analysis, is hydrodynamically squeezed into a narrow stream by two sheath flows so that the particles/cells flow individually through a detection region. The detection of the particles/cells emitted fluorescence is carried out by using a collection fiber placed orthogonally to the flow. The device is based on silicon hollow core antiresonant reflecting optical waveguides (ARROWs). ARROW geometry allows one to use the same channel to guide both the sample stream and the fluorescence excitation light, leading to a simplification of the optical configuration and to an increase of the signal-to-noise ratio. The integrated micro flow cytometer has been characterized by using biological samples marked with standard fluorochromes. The experimental investigation confirms the success of the proposed microdevice in the detection of cells.
引用
收藏
页码:1267 / 1272
页数:6
相关论文
共 12 条
[1]   Silicon micromachined hollow optical waveguides for sensing applications [J].
Bernini, R ;
Campopiano, S ;
Zeni, L .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2002, 8 (01) :106-110
[2]  
Chung S, 2003, MICROSYST TECHNOL, V9, P525, DOI [10.1007/s00542-003-0302-2, 10.1007/S00542-003-0302-2]
[3]  
GRUNDE C, 2004, FEMS MICORBIOL ECOL, V49, P37
[4]   High throughput particle analysis: Combining dielectrophoretic particle focussing with confocal optical detection [J].
Holmes, D ;
Morgan, H ;
Green, NG .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1621-1630
[5]   Microfluidics for flow cytometric analysis of cells and particles [J].
Huh, D ;
Gu, W ;
Kamotani, Y ;
Grotberg, JB ;
Takayama, S .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (03) :R73-R98
[6]   Use of air-liquid two-phase flow in hydrophobic microfluidic channels for disposable flow cytometers [J].
Huh, D ;
Tung, YC ;
Wei, HH ;
Grotberg, JB ;
Skerlos, SJ ;
Kurabayashi, K ;
Takayama, S .
BIOMEDICAL MICRODEVICES, 2002, 4 (02) :141-149
[7]   Development of a microfluidic device for fluorescence activated cell sorting [J].
Krüger, J ;
Singh, K ;
O'Neill, A ;
Jackson, C ;
Morrison, A ;
O'Brien, P .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (04) :486-494
[8]   Micro flow cytometers with buried SU-8/SOG optical waveguides [J].
Lee, GB ;
Lin, CH ;
Chang, GL .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 103 (1-2) :165-170
[9]   Micromachined flow cytometers with embedded etched optic fibers for optical detection [J].
Lin, CH ;
Lee, GB .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :447-453
[10]   Flow cytometry of Escherichia coli on nucrifluidic devices [J].
McClain, MA ;
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5334-5338