Quantitative assessment of flow velocity-estimation algorithms for optical Doppler tomography imaging

被引:21
作者
Piao, DQ [1 ]
Otis, LL
Dutta, NK
Zhu, Q
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Storrs, CT 06269 USA
[2] Univ Penn, Sch Dent Med, Philadelphia, PA 19104 USA
[3] Univ Connecticut, Dept Phys, Storrs, CT 06269 USA
关键词
D O I
10.1364/AO.41.006118
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a quantitative comparison of three categories of velocity estimation algorithms, including centroid techniques (the adaptive centroid technique and the weighted centroid technique), the sliding-window filtering technique, and correlation techniques (autocorrelation and cross correlation). We introduce, among these five algorithms, two new algorithms: weighted centroid and sliding-window filtering. Simulations and in vivo blood flow data are used to assess the velocity estimation accuracies of these algorithms. These comparisons demonstrate that the sliding-window filtering technique is superior to the other techniques in terms of velocity estimation accuracy and robustness to noise. (C) 2002 Optical Society of America.
引用
收藏
页码:6118 / 6127
页数:10
相关论文
共 16 条
[2]   Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography [J].
Chen, ZP ;
Milner, TE ;
Srinivas, S ;
Wang, XJ ;
Malekafzali, A ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (14) :1119-1121
[3]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[4]  
HATLE L, 1982, DOPPLER ULTRASOUND C
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy [J].
Izatt, JA ;
Kulkami, MD ;
Yazdanfar, S ;
Barton, JK ;
Welch, AJ .
OPTICS LETTERS, 1997, 22 (18) :1439-1441
[7]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[8]   Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography [J].
Kulkarni, MD ;
van Leeuwen, TG ;
Yazdanfar, S ;
Izatt, JA .
OPTICS LETTERS, 1998, 23 (13) :1057-1059
[9]  
Li PC, 2001, IEEE T ULTRASON FERR, V48, P1084
[10]   Real-time in vivo colors Doppler optical coherence tomography [J].
Rollins, AM ;
Yazdanfar, S ;
Barton, JK ;
Izatt, JA .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) :123-129