Emphysema: Effect of reconstruction algorithm on CT imaging measures

被引:159
作者
Boedeker, KL [1 ]
McNitt-Gray, MF [1 ]
Rogers, SR [1 ]
Truong, DA [1 ]
Brown, MS [1 ]
Gjertson, DW [1 ]
Goldin, JG [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Los Angeles, CA 90095 USA
关键词
computed tomography (CT); computer programs; electron beam; image processing; emphysema; pulmonary; lung; CT;
D O I
10.1148/radiol.2321030383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the current study, the effects of reconstruction algorithms on quantitative measures derived from computed tomographic (CT) lung images were assessed in patients with emphysema. CT image data sets were reconstructed with a standard algorithm and alternative algorithm(s) for 42 subjects. Algorithms were grouped as overenhancing, sharp, standard, or smooth. Density mask and volume measurements from the alternative algorithm data sets were compared with standard algorithm data sets. The overenhancing category yielded an average shift of 9.4% (ie, a shift in average score from 35.5% to 44.9%); the sharp category, a shift of 2.4%; and the smooth category, a shift of -1.0%. Differences in total lung volume measurements were less than 1%. In conclusion, the CT reconstruction algorithm may strongly affect density mask results, especially for certain reconstruction algorithms. (C) RSNA, 2004.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 19 条
[11]   Quantitative CT of the lung [J].
Goldin, JG .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2002, 40 (01) :145-+
[12]  
HUBER PJ, 1967, 5TH P BERK S MATH ST, V1, P221
[13]   CT lung densitometry: Dependence of CT number histograms on sample volume and consequences for scan protocol comparability [J].
Kemerink, GJ ;
Kruize, HH ;
Lamers, RJS ;
vanEngelshoven, JMA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) :948-954
[14]   CT densitometry of the lungs: Scanner performance [J].
Kemerink, GJ ;
Lamers, RJS ;
Thelissen, GRP ;
vanEngelshoven, JMA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) :24-33
[15]   SCANNER CONFORMITY IN CT DENSITOMETRY OF THE LUNGS [J].
KEMERINK, GJ ;
LAMERS, RJS ;
THELISSEN, GRP ;
VANENGELSHOVEN, JMA .
RADIOLOGY, 1995, 197 (03) :749-752
[16]   LIMITATIONS OF COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF EMPHYSEMA [J].
MILLER, RR ;
MULLER, NL ;
VEDAL, S ;
MORRISON, NJ ;
STAPLES, CA .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (04) :980-983
[17]   DENSITY MASK - AN OBJECTIVE METHOD TO QUANTITATE EMPHYSEMA USING COMPUTED-TOMOGRAPHY [J].
MULLER, NL ;
STAPLES, CA ;
MILLER, RR ;
ABBOUD, RT .
CHEST, 1988, 94 (04) :782-787
[18]   Repeatability of lung density measurements with low-dose computed tomography in subjects with α-1-antitrypsin deficiency-associated emphysema [J].
Stolk, J ;
Dirksen, A ;
Van der Lugt, A ;
Hutsebaut, J ;
Mathieu, J ;
De Ree, J ;
Reiber, JHC ;
Stoel, BC .
INVESTIGATIVE RADIOLOGY, 2001, 36 (11) :648-651