Determination of total bilirubin in human serum by chemiluminescence from the reaction of bilirubin and peroxynitrite

被引:59
作者
Lu, C
Lin, JM
Huie, CW
机构
[1] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
[2] Hong Kong Baptist Univ, Dept Chem, Kowloon, Hong Kong, Peoples R China
关键词
chemiluminescence; flow injection; peroxynitrite; total bilillibin; human serum;
D O I
10.1016/j.talanta.2003.10.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Peroxynitrous acid (ONOOH) was produced by the on-line reaction of acidified hydrogen peroxide with nitrite in a How system, and peroxynitrite (ONOO-) was generated from ONOOH in NaOH solution. A weak chemiluminescent (CL) emission was observed due to the production of singlet oxygen (10,) during the decomposition of ONOO-. Bilirubin and its conjugate were found to enhance the CL emission Of 102 in a suitable micellar medium. For the first time, the feasibility of employing the present CL system for the sensitive and selective determination of total bilirubin contents in human serum was demonstrated and the results were compared with certified values. The present method showed a great improvement on overcoming bis(2,4,6-trichlorophenyl)oxalate CL highly insolubility in aqueous Solution and exhibiting higher tolerance towards interferences than redox reaction of bilirubin with various oxidizing agents Such as sodium hypochlorite and iodine. The recoveries of bilirubin were found to fall in the range between 95 and 108%. The detection limits (S/N = 3) for bilirubin and its conjugate were determined to be 10 and 8 ng ml(-1), respectively. The relative standard deviations (R.S.D.) for the Consecutive CL detection of a series of bilirubin (30 mug l(-1)) and bilirubin ditaurite (25 mug l(-1)) were 3.2 and 2.9% (n = 11), respectively. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 337
页数:5
相关论文
共 23 条
[1]   DETECTION OF BILIRUBIN USING SURFACTANT FLUORESCENCE ENHANCEMENT AND VISIBLE LASER FLUOROMETRY [J].
AIKEN, JH ;
HUIE, CW .
ANALYTICAL LETTERS, 1991, 24 (01) :167-180
[2]   FLUORESCENCE STOPPED-FLOW STUDY OF RELAXATION PROCESSES IN BINDING OF BILIRUBIN TO SERUM ALBUMINS [J].
CHEN, RF .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1974, 160 (01) :106-112
[3]   FLUORESCENCE OF BILIRUBIN [J].
CU, A ;
BELLAH, GG ;
LIGHTNER, DA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1975, 97 (09) :2579-2580
[4]   MICELLAR-ENHANCED AQUEOUS PEROXYOXALATE CHEMILUMINESCENCE [J].
DAN, N ;
LAU, ML ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1766-1771
[5]   Chemiluminescence as a diagnostic tool. A review [J].
Dodeigne, C ;
Thunus, L ;
Lejeune, R .
TALANTA, 2000, 51 (03) :415-439
[6]   FLOW-INJECTION SPECTROPHOTOMETRIC ENZYMATIC AND NONENZYMATIC METHODS FOR THE DETERMINATION OF DIRECT AND TOTAL BILIRUBIN IN SERUM [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1993, 276 (02) :271-279
[7]   Formation of peroxynitrate from the reaction of peroxynitrite with CO2:: Evidence for carbonate radical production [J].
Goldstein, S ;
Czapski, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (14) :3458-3463
[8]   IMPROVEMENT IN 10,10'-DIMETHYL-9,9'-BIACRIDINIUM DINITRATE ANALYTICAL CHEMI-LUMINESCENCE MEASUREMENTS BY USE OF REACTIVE HYDROXIDE COUNTERION ALKYLTRIMETHYLAMMONIUM MICELLAR SURFACTANTS [J].
INGVARSSON, A ;
FLURER, CL ;
RIEHL, TE ;
THIMMAIAH, KN ;
WILLIAMS, JM ;
HINZE, WL .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2047-2055
[9]   QUANTITATIVE GENERATION OF SINGLET ((1)DELTA(G)) OXYGEN FROM ACIDIFIED AQUEOUS PEROXYNITRITE PRODUCED BY THE REACTION OF NITRIC-OXIDE AND SUPEROXIDE ANION [J].
KHAN, AU .
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1995, 10 (06) :329-333
[10]   The decomposition of peroxynitrite to nitroxyl onion (NO-) and singlet oxygen in aqueous solution [J].
Khan, AU ;
Kovacic, D ;
Kolbanovskiy, A ;
Desai, M ;
Frenkel, K ;
Geacintov, NE .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (07) :2984-2989