Reducing water usage with rotary regenerative gas/gas heat exchangers in natural gas-fired power plants with post-combustion carbon capture

被引:17
作者
Herraiz, Laura [1 ]
Hogg, Dougal [2 ]
Cooper, Jim [2 ]
Gibbins, Jon [1 ]
Lucquiaud, Mathieu [1 ]
机构
[1] Univ Edinburgh, Sch Engn, Edinburgh EH9 3JL, Midlothian, Scotland
[2] Howden Global, Old Govan PA4 8XJ, Renfrew, Scotland
基金
英国工程与自然科学研究理事会;
关键词
Post-combustion carbon capture; Combined cycle gas turbine; Dry air-cooled system; Regenerative rotary heat exchanger; Exhaust gas recirculation; CO2; CAPTURE; GENERATION;
D O I
10.1016/j.energy.2015.07.032
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
It is possible to greatly mitigate the increase of water usage associated with the addition of carbon capture to fossil fuel power generation. This article presents a first-of-a-kind feasibility study of a series of technology options with rotary regenerative gas/gas heat exchangers for the management of the water balance around post-combustion carbon capture process integrated with CCGT (Combined Cycle Gas Turbine) plants with and without EGR (exhaust gas recirculation). Hybrid cooling configurations with a gas/gas heat exchanger upstream of the direct contact cooler reduce cooling and process water demand by 67% and 35% respectively compared to a wet system where the flue gas is primarily cooled prior to the absorber in larger direct contact coolers. The CO2-depleted gas stream is then reheated above 70 degrees C with enough buoyancy to rise through the stack. Dry air-cooled configurations, relying on ambient air as the cooling medium, eliminate the use of process and cooling water prior to the absorber and the temperature of the flue gas entering the absorber is unchanged. Rotary regenerative heat exchangers do not introduce significant additional pressure drop and gas leakage from a high CO2 concentration stream to a stream with lower concentration can be minimized to acceptable levels with available strategies using a purge and a scavenging slipstream from the higher pressure flow. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1994 / 2005
页数:12
相关论文
共 23 条
[1]
[Anonymous], WAT ABSTR IRR MAN IN
[2]
[Anonymous], 2004, PH433 IEA GHG
[3]
Electricity generation and cooling water use: UK pathways to 2050 [J].
Byers, Edward A. ;
Hall, Jim W. ;
Amezaga, Jaime M. .
GLOBAL ENVIRONMENTAL CHANGE-HUMAN AND POLICY DIMENSIONS, 2014, 25 :16-30
[4]
Cooper J, 1991, INT POW GEN C ASME
[5]
Assessment of the consumption of water and construction materials in state-of-the-art fossil fuel power generation technologies involving CO2 capture [J].
Cormos, Calin-Cristian ;
Vatopoulos, Konstantinos ;
Tzimas, Evangelos .
ENERGY, 2013, 51 :37-49
[6]
Department of Energy and Climate Change, 2010, 1 DEM FRONT ENG DES
[7]
EBTF European best practice guidelines for assessment of CO2 capture technologies, 2011, 213569 CESAR GA
[8]
Application of Exhaust Gas Recirculation in a DLN F-Class Combustion System for Postcombustion Carbon Capture [J].
ElKady, Ahmed M. ;
Evulet, Andrei ;
Brand, Anthony ;
Ursin, Tord Peter ;
Lynghjem, Arne .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2009, 131 (03)
[9]
Thermodynamic assessment of amine based CO2 capture technologies in power plants based on European Benchmarking Task Force methodology [J].
Fernandez, E. Sanchez ;
Goetheer, E. L. V. ;
Manzolini, G. ;
Macchi, E. ;
Rezvani, S. ;
Vlugt, T. J. H. .
FUEL, 2014, 129 :318-329
[10]
Howden, 2008, HJR PC B 01 PREHEATE