Thermodynamic assessment of amine based CO2 capture technologies in power plants based on European Benchmarking Task Force methodology

被引:117
作者
Fernandez, E. Sanchez [1 ]
Goetheer, E. L. V. [1 ]
Manzolini, G. [2 ]
Macchi, E. [2 ]
Rezvani, S. [3 ]
Vlugt, T. J. H. [4 ]
机构
[1] TNO Gas Treatment, NL-2628 CA Delft, Netherlands
[2] Politecn Milan, Dipartimento Energia, I-20156 Milan, Italy
[3] Murdoch Univ, Sch Engn & Informat Technol, Murdoch, WA 6150, Australia
[4] Delft Univ Technol, NL-2628 CB Delft, Netherlands
关键词
Amine-scrubbing; Post-combustion CO2 capture; Monoethanolamine; 2-Amino-2-Methyl-1-Propanol; Piperazine; CARBON CAPTURE; COMBINED-CYCLE; PERFORMANCE; PART; CONFIGURATIONS; EFFICIENCY; COSTS;
D O I
10.1016/j.fuel.2014.03.042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
Post combustion CO2 capture (PCC) with amine solvents is seen as one of the possible technologies which can be implemented in the near term to significantly reduce CO2 emissions from fossil fuel power plants. One of the major concerns for its implementation at large scale in power plants is the high capital and operating costs of the technology. This paper examines the performance of advanced supercritical (ASC) pulverised coal and natural gas combined cycle (NGCC) power plants with two post-combustion CO2 capture units. The capture units are based on chemical absorption with an advanced amine solvent, CESAR-1, which is an aqueous solution of 2-Amino-2-Methyl-Propanol (AMP) and piperazine (PZ), and the conventional Monoethanolamine (MEA) solvent. The comparison between the mentioned technologies is based on the technical assumptions and method provided by the European Benchmarking Taskforce (EBTF) methodology, which is a first attempt for establishing a common European Standard for comparative studies. The resulting net electric efficiencies for the power plants without capture are 45.25% and 58.3% for the ASC PC and NGCC cases respectively. When CO2 capture is applied, the net electrical efficiencies of the studied plants decreases. In the ASC power plant, the MEA capture unit decreases the efficiency by 11.7 percentage points, while the CESAR-1 capture unit decreases the efficiency by 9.4 percentage points. For the NGCC power plant, the reductions are 8.4 and 7.6 percentage points for the MEA and CESAR-1 capture units respectively. Therefore, the evaluation of CESAR-1 under the EBTF standards shows a reduction on power production penalty of 25% for the coal fired plant and 12% for the gas fired plant compared to conventional MEA. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:318 / 329
页数:12
相关论文
共 46 条
[1]
CO2 capture from power plants -: Part II.: A parametric study of the economical performance based on mono-ethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (02) :135-142
[2]
CO2 capture from power plants.: Part I.: A parametric study of the technical-performance based on monoethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Schneiders, Leon H. J. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (01) :37-46
[3]
Optimized process configurations of post-combustion CO2 capture for natural-gas-fired power plant-Exergy analysis [J].
Amrollahi, Zeinab ;
Ertesvag, Ivar S. ;
Bolland, Olav .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (06) :1393-1405
[4]
[Anonymous], 2010, Cost and Performance Baseline for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity, V1
[5]
[Anonymous], 2008, CO2 Capture and Storage - a Key Carbon Abatement Option
[6]
Characterization and comparison of the CO2 absorption performance into single and blended alkanolamines in a packed column [J].
Aroonwilas, A ;
Veawab, A .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (09) :2228-2237
[7]
High efficiency electric power generation:: The environmental role [J].
Beer, Janos M. .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2007, 33 (02) :107-134
[8]
Braitsch J., 2012, GHGT 11
[9]
CAESAR, 2011, CAESAR FP7 PROJ
[10]
Chapel D, 1999, ENG ANN M