Clinical assessment of a new real time 3D quantitative coronary angiography system: Evaluation in stented vessel segments

被引:44
作者
Gradaus, R [1 ]
Mathies, K [1 ]
Breithardt, G [1 ]
Boecker, D [1 ]
机构
[1] Univ Hosp, Dept Cardiol & Angiol, Munster, Germany
关键词
quantitative coronary angiography; 3D reconstruction software system;
D O I
10.1002/ccd.20775
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Foreshortening is a recognized problem that is present in angiography and results from views that are not perpendicular to coronary lesions. This limits visual coronary analysis as well as 2D quantitative coronary angiography systems (QCA). The CardiOp-B System (R) is a 3D image acquisition and processing software system designed as an add-on to conventional X-ray angiography system. CardiOp-B's features include real time and off line analysis with comprehensive 3D reconstruction integrating all of the available information of two 2D vessel angiographies into one 3D image. It was the aim of the study to analyze the accuracy of this new 3D QCA system. Methods: 313 QCA was performed in 50 patients (age 64 +/- 10.9; 84% male; LV-EF 63 16%) measuring 61 stents during high-pressure inflation (diameter: 2.25-4 mm; length: 8-32 mm). The obtained values (proximal and distal stent diameter, stent length) were correlated with the predefined size of the stents at the used inflation pressure. Results: The linear correlation for the proximal stent diameter was Stent(prox)= 0.03 + 0.93 x real stent size (r(2) = 0.85). The linear correlation for the distal stent diameter was Stent(distai)= -0.03 + 0.89 x real stent size (r(2) = 0.81). The linear correlation for the stent length was Stent(length)= -0.61 + 1.02 x real stent length (r(2) = 0.98). Conclusions: The CardiOp-B System (R) is a new 3D QCA system with a high linear correlation between the real vessel size and the obtained vessel dimension. It provides real time or off line accurate and comprehensive diagnostic information to the interventional cardiologist without changing the basic coronary angiography procedure.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 12 条
[1]   Selection of coronary stents [J].
Colombo, A ;
Stankovic, G ;
Moses, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (06) :1021-1033
[2]   QUANTITATIVE CORONARY ANGIOGRAPHY (QCA) IN INTERVENTIONAL CARDIOLOGY - CLINICAL-APPLICATION OF QCA MEASUREMENTS [J].
FOLEY, DP ;
ESCANED, J ;
STRAUSS, BH ;
DIMARIO, C ;
HAASE, J ;
KEANE, D ;
HERMANS, WRM ;
RENSING, BJ ;
DEFEYTER, PJ ;
SERRUYS, PW .
PROGRESS IN CARDIOVASCULAR DISEASES, 1994, 36 (05) :363-384
[3]   Angiographic views used for percutaneous coronary interventions: A three-dimensional analysis of physician-determined vs. computer-generated views [J].
Green, NE ;
Chen, SYJ ;
Hansgen, AR ;
Messenger, JC ;
Groves, BM ;
Carroll, JD .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 64 (04) :451-459
[4]   Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events [J].
Gyöngyösi, M ;
Yang, P ;
Khorsand, A ;
Glogar, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1580-1589
[5]   VARIABILITY IN MEASURES OF CORONARY LUMEN DIMENSIONS USING QUANTITATIVE CORONARY ANGIOGRAPHY [J].
HERRINGTON, DM ;
SIEBES, M ;
SOKOL, DK ;
SIU, CO ;
WALFORD, GD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1068-1074
[6]   A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries [J].
Klein, JL ;
Hoff, JG ;
Peifer, JW ;
Folks, R ;
Cooke, CD ;
King, SB ;
Garcia, EV .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (02) :75-87
[7]   Stented segment length as an independent predictor of restenosis [J].
Kobayashi, Y ;
De Gregorio, J ;
Kobayashi, N ;
Akiyama, T ;
Reimers, B ;
Finci, L ;
Di Mario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (03) :651-659
[8]   Effects of Stent length and lesion length on coronary restenosis [J].
Mauri, L ;
O'Malley, AJS ;
Cutlip, DE ;
Ho, KKL ;
Popma, JJ ;
Chauhan, MS ;
Baim, DS ;
Cohen, DJ ;
Kuntz, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (11) :1340-1346
[9]   3D coronary reconstruction from routine single-plane coronary angiograms: Clinical validation and quantitative analysis of the right coronary artery in 100 patients [J].
Messenger, JC ;
Chen, SYJ ;
Carroll, JD ;
Burchenal, JEB ;
Kioussopoulos, K ;
Groves, BM .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (06) :413-427
[10]   Effects of Palmaz-Schatz stents on angled coronary arteries [J].
Phillips, PS ;
Alfonso, F ;
Segovia, J ;
Goicolea, J ;
Hernandez, R ;
Banuelos, C ;
FernandezOrtiz, A ;
PerezVizcayno, MJ ;
Macaya, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02) :191-&