Wear of a highly cross-linked polyethylene liner associated with metallic deposition on a ceramic femoral head

被引:16
作者
Della Valle, AG
Doty, S
Gradl, G
Labissiere, A
Nestor, BJ
机构
[1] Hosp Special Surg, New York, NY 10021 USA
[2] Kardinal Schwarzenberg Krankenhaus, Schwarzach, Austria
关键词
total hip arthroplasty; dislocation; ceramic; titanium deposition; polyethylene wear;
D O I
10.1016/j.arth.2003.12.065
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A 68-year-old patient underwent revision surgery for recurrent dislocation of a ceramic-on-polyethylene uncemented hip arthroplasty implanted 6 months previously. The aluminum oxide femoral head was found to have titanium deposition measuring 5 by 10 mm in an area articulating with the highly cross-linked polyethylene liner. The liner was observed to possess severe scratching produced by articulation with the titanium deposited on the ceramic head. Despite improved scratch resistance of ceramic-bearing surfaces, irregularities introduced by metallic deposition after recurrent dislocation can damage a highly cross-linked polyethylene liner. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:532 / 536
页数:5
相关论文
共 9 条
[1]
ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]
Callaway GH, 1995, J ARTHROPLASTY, V10, P855
[3]
Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty [J].
Hummer, CD ;
Rothman, RH ;
Hozack, WJ .
JOURNAL OF ARTHROPLASTY, 1995, 10 (06) :848-850
[4]
Drain entrapment and titanium to ceramic head deposition - Two unique complications following closed reduction of a dislocated total hip arthroplasty [J].
Luchetti, WT ;
Copley, LA ;
Vresilovic, EJ ;
Black, J ;
Steinberg, ME .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :713-717
[5]
NEW PROSPECTS FOR A PROLONGED FUNCTIONAL LIFE-SPAN OF ARTIFICIAL HIP JOINTS BY USING MATERIAL COMBINATION POLYETHYLENE-ALUMINUM OXIDE CERAMIC-METAL [J].
SEMLITSCH, M ;
LEHMANN, M ;
WEBER, H ;
DOERRE, E ;
WILLERT, HG .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (04) :537-552
[6]
The use of a constrained acetabular component for recurrent dislocation [J].
Shapiro, GS ;
Weiland, DE ;
Markel, DC ;
Padgett, DE ;
Sculco, TP ;
Pellicci, PM .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :250-258
[7]
THOMSEN M, 2003, HIP INT, V13, P107
[8]
Willmann G, 2000, CLIN ORTHOP RELAT R, P22
[9]
DISLOCATIONS AFTER TOTAL HIP-ARTHROPLASTY [J].
WOO, RYG ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1295-1306