Integrated multi-level quality control for proteomic profiling studies using mass spectrometry

被引:19
作者
Cairns, David A. [1 ,2 ]
Perkins, David N. [1 ]
Stanley, Anthea J. [1 ]
Thompson, Douglas [3 ]
Barrett, Jennifer H. [1 ,2 ]
Selby, Peter J. [1 ]
Banks, Rosamonde E. [1 ]
机构
[1] St James Univ Hosp, Leeds Inst Mol Med, Canc Res UK Clin Ctr, Clin & Biomed Proteom Grp, Leeds LS9 7TF, W Yorkshire, England
[2] St James Univ Hosp, Leeds Inst Mol Med, Epidemiol & Biostat Sect, Leeds LS9 7TF, W Yorkshire, England
[3] Leeds Gen Infirm, Dept Clin Biochem & Immunol, Leeds LS1 3EX, W Yorkshire, England
关键词
D O I
10.1186/1471-2105-9-519
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Proteomic profiling using mass spectrometry (MS) is one of the most promising methods for the analysis of complex biological samples such as urine, serum and tissue for biomarker discovery. Such experiments are often conducted using MALDI-TOF (matrix-assisted laser desorption/ionisation time-of-flight) and SELDI-TOF (surface-enhanced laser desorption/ionisation time-of-flight) MS. Using such profiling methods it is possible to identify changes in protein expression that differentiate disease states and individual proteins or patterns that may be useful as potential biomarkers. However, the incorporation of quality control (QC) processes that allow the identification of low quality spectra reliably and hence allow the removal of such data before further analysis is often overlooked. In this paper we describe rigorous methods for the assessment of quality of spectral data. These procedures are presented in a user-friendly, web-based program. The data obtained post-QC is then examined using variance components analysis to quantify the amount of variance due to some of the factors in the experimental design. Results: Using data from a SELDI profiling study of serum from patients with different levels of renal function, we show how the algorithms described in this paper may be used to detect systematic variability within and between sample replicates, pooled samples and SELDI chips and spots. Manual inspection of those spectral data that were identified as being of poor quality confirmed the efficacy of the algorithms. Variance components analysis demonstrated the relatively small amount of technical variance attributable to day of profile generation and experimental array. Conclusion: Using the techniques described in this paper it is possible to reliably detect poor quality data within proteomic profiling experiments undertaken by MS. The removal of these spectra at the initial stages of the analysis substantially improves the confidence of putative biomarker identification and allows inter-experimental comparisons to be carried out with greater confidence.
引用
收藏
页数:19
相关论文
共 58 条
  • [1] Optimization and evaluation of surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) with reversed-phase protein arrays for protein profiling
    Aivado, M
    Spentzos, D
    Alterovitz, G
    Otu, HH
    Grall, F
    Giagounidis, AAN
    Wells, M
    Cho, JY
    Germing, U
    Czibere, A
    Prall, WC
    Porter, C
    Ramoni, MF
    Libermann, TA
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (02) : 133 - 140
  • [2] [Anonymous], 1979, Multivariate analysis
  • [3] Reproducibility of SELDI-TOF protein patterns in serum: comparing datasets from different experiments
    Baggerly, KA
    Morris, JS
    Coombes, KR
    [J]. BIOINFORMATICS, 2004, 20 (05) : 777 - U710
  • [4] Baggerly KA, 2005, CANCER INFORM, V1, P9
  • [5] Influences of blood sample processing on low-molecular-weight proteome identified by surface-enhanced laser desorption/ionization mass spectrometry
    Banks, RE
    Stanley, AJ
    Cairns, DA
    Barrett, JH
    Clarke, P
    Thompson, D
    Selby, PJ
    [J]. CLINICAL CHEMISTRY, 2005, 51 (09) : 1637 - 1649
  • [6] Bates D., 2005, R News, V5, P27, DOI DOI 10.1159/000323281
  • [7] Standardization of calibration and quality control using surface enhanced laser desorption ionization-time of flight-mass spectrometry
    Bons, JAP
    de Boer, D
    van Dieijen-Visser, MP
    Wodzig, WKWH
    [J]. CLINICA CHIMICA ACTA, 2006, 366 (1-2) : 249 - 256
  • [8] CAIRNS DA, 2008, PROTEOMICS IN PRESS
  • [9] Proteomic profiling using mass spectrometry does normalising by total ion current potentially mask some biological differences?
    Cairns, David A.
    Thompson, Douglas
    Perkins, David N.
    Stanley, Anthea J.
    Selby, Peter J.
    Banks, Rosamonde E.
    [J]. PROTEOMICS, 2008, 8 (01) : 21 - 27
  • [10] Interpretation of mass spectrometry data for high-throughput proteomics
    Chamrad, DC
    Koerting, G
    Gobom, J
    Thiele, H
    Klose, J
    Meyer, HE
    Blueggel, M
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (07) : 1014 - 1022