The DeBakey ventricular assist device:: Current status in 1997

被引:19
作者
Tayama, E
Olsen, DB
Ohashi, Y
Benkowski, R
Morley, D
Noon, GP
Nosé, Y
DeBakey, ME
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[2] Univ Utah, Artificial Heart Res Lab, Salt Lake City, UT USA
[3] MicroMed Technol Inc, Woodlands, TX USA
关键词
artificial hearts; ventricular assist device; axial flow blood pump; implantable device; DeBakey ventricular assist device;
D O I
10.1046/j.1525-1594.1999.06300.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In 1993, the development began of a small axial now blood pump, the DeBakey ventricular assist device (VAD). The material was recently converted to a titanium alloy, and a waterproof pump package was incorporated for long-term intracorporeal circulation. Thirteen intrathoracic implantations in calves were achieved. Nine animals survived the 2 week perioperative period and were supported for a range of 26-93 days. The first study had low flow due to poor anatomical fit of the straight cannula. In contrast, a curved cannula used subsequently provided a good anatomical fit with sufficient flow. Mean flow of 4.4 L/min was sustained with 9,900 rpm and required power was an average of 8.8 W. No thromboembolic evidences were observed in any case, and the plasma free hemoglobin bin level was maintained lower than 5 mg/dl, except in the early postoperative period. Three animals were terminated because of bleeding due to anticoagulant mismanagement. Electric interference (n = 1) and drive line breakage/fault (n = 2) were observed as device-related failures. Minor modifications were made to the drive line. in conclusion, the DeBakey VAD demonstrated adequate basic: performance and biocompatibility. The highly reliable mechanical components and improved electrical parts are promising for a long-term implantable cardiac prosthesis.
引用
收藏
页码:1113 / 1116
页数:4
相关论文
共 9 条
  • [1] DAMM G, 1993, ARTIF ORGANS, V17, P609
  • [2] AXIAL-FLOW VENTRICULAR ASSIST DEVICE - SYSTEM PERFORMANCE CONSIDERATIONS
    DAMM, G
    MIZUGUCHI, K
    ABER, G
    BACAK, J
    AKKERMAN, J
    BOZEMAN, R
    SVEJKOVSKY, P
    TAKATANI, S
    NOSE, Y
    NOON, GP
    DEBAKEY, ME
    [J]. ARTIFICIAL ORGANS, 1994, 18 (01) : 44 - 48
  • [3] Improved left ventricular function after chronic left ventricular unloading
    Frazier, OH
    Benedict, CR
    Radovancevic, B
    Bick, RJ
    Capek, P
    Springer, WE
    Macris, MP
    Delgado, R
    Buja, LM
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (03) : 675 - 681
  • [4] BIOENGINEERING EFFORTS IN DEVELOPING ARTIFICIAL HEARTS AND ASSISTORS
    HALL, CW
    LIOTTA, D
    DEBAKEY, ME
    [J]. AMERICAN JOURNAL OF SURGERY, 1967, 114 (01) : 24 - &
  • [5] Ex vivo evaluation of the NASA/DeBakey axial flow ventricular assist device - Results of a 2 week screening test
    Kawahito, K
    Benkowski, R
    Otsubo, S
    Rosenbaum, B
    Moreland, R
    Noon, GP
    Nose, Y
    DeBakey, ME
    [J]. ASAIO JOURNAL, 1996, 42 (05) : M754 - M757
  • [6] Kawahito K, 1997, ARTIF ORGANS, V21, P339
  • [7] DEVELOPMENT OF THE BAYLOR NASA AXIAL-FLOW VENTRICULAR ASSIST DEVICE - IN-VITRO PERFORMANCE AND SYSTEMATIC HEMOLYSIS TEST-RESULTS
    MIZUGUCHI, K
    DAMM, GA
    BOZEMAN, RJ
    AKKERMAN, JW
    ABER, GS
    SVEJKOVSKY, PA
    BACAK, JW
    ORIME, Y
    TAKATANI, S
    NOSE, Y
    NOON, GP
    DEBAKEY, ME
    [J]. ARTIFICIAL ORGANS, 1994, 18 (01) : 32 - 43
  • [8] OHTSUBO S, 1996, CARDIOVASC ENG, V1, P27
  • [9] Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices
    Slater, JP
    Rose, EA
    Levin, HR
    Frazier, OH
    Roberts, JK
    Weinberg, AD
    Oz, MC
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (05) : 1321 - 1327