An on-line pre-concentration system for determination of cadmium in drinking water using FAAS

被引:37
作者
dos Santos, Walter N. L. [1 ]
Costa, Jorge L. O.
Araujo, Rennan G. O.
de Jesus, Djane S.
Costa, Antonio C. S.
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Ctr Fed Educ Tecnol Bahia, BR-40300010 Salvador, BA, Brazil
关键词
cadmium determination; drinking water; FAAS; pre-concentration;
D O I
10.1016/j.jhazmat.2006.03.046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L-1 and elution concentration of 1.0 mol L-1, this system allows the determination of cadmium with detection limit (LD) (3 sigma/S) of 20.0ng L-1 and quantification limit (LQ) (10 sigma/S) of 64ngL(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 mu g L-1, respectively, and a pre-concentration factor of 158 for a sample volume of 20.0mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 mu g L-1. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:1357 / 1361
页数:5
相关论文
共 24 条
[1]  
[Anonymous], 1998, HLTH CRIT OTH SUPP I
[2]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[3]   Cloud point extraction as a procedure of separation and pre-concentration for metal determination using spectroanalytical techniques: A review [J].
Bezerra, MD ;
Arruda, MAZ ;
Ferreira, SLC .
APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (04) :269-299
[4]  
Braun T., 1985, POLYURETHANE FOAM SO
[5]   Knotted reactors and their role in flow-injection on-line preconcentration systems coupled to atomic spectrometry-based detectors [J].
Cerutti, S ;
Martinez, LD ;
Wuilloud, RG .
APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (01) :71-101
[6]   Optimization of the preconcentration system of cadmium with 1(2-thiazolylazo)-p-cresol using a knotted reactor and flame atomic absorption spectrometric detection [J].
Cerutti, S ;
Ferreira, SLC ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
JOURNAL OF HAZARDOUS MATERIALS, 2004, 112 (03) :279-283
[7]   Determination of cadmium in biological samples [J].
Davis, AC ;
Wu, P ;
Zhang, XF ;
Hou, XD ;
Jones, BT .
APPLIED SPECTROSCOPY REVIEWS, 2006, 41 (01) :35-75
[8]   Polyurethane foam as a sorbent for continuous flow analysis: Preconcentration and spectrophotometric determination of zinc in biological materials [J].
de Jesus, DS ;
Casella, RJ ;
Ferreira, SLC ;
Costa, ACS ;
de Carvalho, MS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :263-269
[9]   Multivariate optimization and validation studies in on-line pre-concentration system for lead determination in drinking water and saline waste from oil refinery [J].
dos Santos, WL ;
dos Santos, CMM ;
Costa, JLO ;
Andrade, HMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2004, 77 (02) :123-129
[10]   Application of three-variables Doehlert matrix for optimisation of an on-line pre-concentration system for zinc determination in natural water samples by flame atomic absorption spectrometry [J].
dos Santos, WNL ;
Santos, CMC ;
Ferreira, SLC .
MICROCHEMICAL JOURNAL, 2003, 75 (03) :211-221